NanoAndMore USA does not ship to your country
Uncoated AFM Tips
AFM probes with uncoated AFM tips
Sort by:
265 results


3XC-NN
AFM Probe with 3 Different AFM Cantilevers for Various Applications and AFM Tips at the Very End of the AFM Cantilevers
Coating:
none
Tip Shape: Optimized Positioning
Tip Shape: Optimized Positioning
AFM Cantilevers: 3
1
2
3
F
17 kHz
150 kHz
75 kHz
C
0.3 N/m
9 N/m
2.5 N/m
L
500 µm
175 µm
240 µm


HQ:XSC11/No Al
AFM Probe with 4 Different Cantilevers for Various Applications
Coating:
none
Tip Shape: Rotated
Tip Shape: Rotated
AFM Cantilevers: 4
1
2
3
4
F
15 kHz
80 kHz
155 kHz
350 kHz
C
0.2 N/m
2.7 N/m
7 N/m
42 N/m
L
500 µm
210 µm
150 µm
100 µm


All-In-One
AFM Probe with 4 Different AFM Cantilevers for Various Applications
Coating:
none
Tip Shape: Rotated
Tip Shape: Rotated
AFM Cantilevers: 4
1
2
3
4
F
15 kHz
80 kHz
150 kHz
350 kHz
C
0.2 N/m
2.7 N/m
7.4 N/m
40 N/m
L
500 µm
210 µm
150 µm
100 µm


SSS-NCL
SuperSharp, Tapping Mode AFM Probe with Long AFM Cantilever
Coating:
none
Tip Shape: Supersharp
Tip Shape: Supersharp
AFM Cantilever:
F
190 kHz
C
48 N/m
L
225 µm


NW-SSS-NCL
SuperSharp, Tapping Mode AFM Probe with Long Cantilever
Coating:
none
Tip Shape: Supersharp
Tip Shape: Supersharp
AFM Cantilever:
F
190 kHz
C
48 N/m
L
225 µm


SSS-FM
SuperSharp, Force Modulation AFM Probe
Coating:
none
Tip Shape: Supersharp
Tip Shape: Supersharp
AFM Cantilever:
F
75 kHz
C
2.8 N/m
L
225 µm


HiRes-C19/Cr-Au
High Resolution, Soft Tapping Mode AFM Probe
Coating:
Reflective Gold
Tip Shape: Supersharp
Tip Shape: Supersharp
AFM Cantilever:
F
65 kHz
C
0.5 N/m
L
125 µm


HiRes-C14/Cr-Au
High Resolution, Soft Tapping Mode AFM Probe
Coating:
Reflective Gold
Tip Shape: Supersharp
Tip Shape: Supersharp
AFM Cantilever:
F
160 kHz
C
5 N/m
L
125 µm


SuperSharp Enhanced
Ultrasharp EBD AFM whisker for high-resolution, non-contact AFM
Coating:
Reflective Aluminum
Tip Shape: Cone Shaped,Supersharp,EBD
Tip Shape: Cone Shaped,Supersharp,EBD
AFM Cantilever:
F
320 kHz
C
40 N/m
L
120 µm


SuperSharpStandard-NCH
SuperSharp diamond-like EBD whisker for non-contact AFM
Coating:
Reflective Aluminum
Tip Shape: Cone Shaped,Supersharp,EBD
Tip Shape: Cone Shaped,Supersharp,EBD
AFM Cantilever:
F
330 kHz
C
40 N/m
L
125 µm


SuperSharp Enhanced-soft
Ultrasharp EBD AFM whisker for high-resolution, soft tapping AFM
Coating:
Reflective Aluminum
Tip Shape: Cone Shaped,Supersharp,EBD
Tip Shape: Cone Shaped,Supersharp,EBD
AFM Cantilever:
F
75 kHz
C
2.8 N/m
L
225 µm
best of the best


AR10T-NCHR
High-Aspect-Ratio, Tilt Compensated Tapping Mode AFM Probe
Coating:
Reflective Aluminum
Tip Shape: High-Aspect-Ratio
Tip Shape: High-Aspect-Ratio
AFM Cantilever:
F
330 kHz
C
42 N/m
L
125 µm


AR5T-NCHR
High-Aspect-Ratio, Tilt Compensated Tapping Mode AFM Probe
Coating:
Reflective Aluminum
Tip Shape: High-Aspect-Ratio
Tip Shape: High-Aspect-Ratio
AFM Cantilever:
F
330 kHz
C
42 N/m
L
125 µm
the industry standard


NW-AR5T-NCHR
High-Aspect-Ratio, Tilt Compensated Tapping Mode AFM Probe
Coating:
Reflective Aluminum
Tip Shape: High-Aspect-Ratio
Tip Shape: High-Aspect-Ratio
AFM Cantilever:
F
330 kHz
C
42 N/m
L
125 µm


TESPA-HAR
High-Aspect-Ratio, Tapping Mode AFM Probe
Coating:
Reflective Aluminum
Tip Shape: High-Aspect-Ratio
Tip Shape: High-Aspect-Ratio
AFM Cantilever:
F
320 kHz
C
42 N/m
L
125 µm


USC-F2-k3
Ultra-Short Cantilever (USC) mainly dedicated to dynamic High-Speed AFM applications in air
Coating:
Reflective Gold
Tip Shape: Cone Shaped,EBD
Tip Shape: Cone Shaped,EBD
AFM Cantilever:
F
2000 kHz
C
3 N/m
L
10 µm


USC-F1.2-k7.3
Ultra-Short Cantilever (USC) mainly dedicated to dynamic High-Speed AFM applications in air
Coating:
Reflective Gold
Tip Shape: Cone Shaped,EBD
Tip Shape: Cone Shaped,EBD
AFM Cantilever:
F
1200 kHz
C
7.3 N/m
L
20 µm
the industry standard


ARROW-UHF
Ultra High Frequency AFM Probe with Tip at the Very End of the Cantilever
Coating:
Reflective Aluminum
Tip Shape: Arrow
Tip Shape: Arrow
AFM Cantilever:
F
2000 kHz
C
x
L
35 µm


4XC-NN
AFM Probe with 4 Different AFM Cantilevers with AFM Tips at the Very End of the AFM Cantilevers
Coating:
none
Tip Shape: Optimized Positioning
Tip Shape: Optimized Positioning
AFM Cantilevers: 4
1
2
3
4
F
17 kHz
75 kHz
150 kHz
1200 kHz
C
0.3 N/m
2.5 N/m
9 N/m
100 N/m
L
500 µm
240 µm
175 µm
65 µm


PPP-CONT
Standard Contact Mode AFM Probe
Coating:
none
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
13 kHz
C
0.2 N/m
L
450 µm