Uncoated AFM Tips

AFM probes with uncoated AFM tips
Sort by:
270 results
New
biotool high resolution
biotool high resolution
EBD carbon AFM whisker with 2 nm radius on soft AFM cantilever
Coating: Reflective Gold
Tip Shape: EBD,Cone Shaped,Supersharp
AFM Cantilever:
F
50 kHz
C
0.1 N/m
L
60 µm
top value
XNC12/Cr-Au BS
XNC12/Cr-Au BS
AFM Probe with 2 Different Gold Coated Silicon Nitride AFM Cantilevers
Coating: Reflective Gold
Tip Shape: Pyramid
AFM Cantilevers: 2
1
2
F
17 kHz
67 kHz
C
0.08 N/m
0.32 N/m
L
200 µm
100 µm
HQ:NSC35/Cr-Au BS
HQ:NSC35/Cr-Au BS
AFM Probe with 3 Different Gold Coated Tapping Mode AFM Cantilevers
Coating: Reflective Gold
Tip Shape: Rotated
AFM Cantilevers: 3
1
2
3
F
205 kHz
300 kHz
150 kHz
C
8.9 N/m
16 N/m
5.4 N/m
L
110 µm
90 µm
130 µm
55AC-NG
55AC-NG

Gold Coated Ultra High Frequency AFM Probe with AFM Tip at the Very End of the AFM Cantilever

Coating: Reflective Gold
Tip Shape: Optimized Positioning
AFM Cantilever:
F
1200 kHz
C
85 N/m
L
65 µm
top value
55AC-NA
55AC-NA

Ultra High Frequency AFM Probe with AFM Tip at the Very End of the AFM Cantilever

Coating: Reflective Aluminum
Tip Shape: Optimized Positioning
AFM Cantilever:
F
1200 kHz
C
85 N/m
L
65 µm
New
OMCL-AC55TS
OMCL-AC55TS
Ultra High Frequency AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating: Reflective Gold
Tip Shape: Optimized Positioning
AFM Cantilever:
F
1600 kHz
C
85 N/m
L
55 µm
55AC-NN
55AC-NN

Ultra High Frequency AFM Probe with AFM Tip at the Very End of the AFM Cantilever

Coating: none
Tip Shape: Optimized Positioning
AFM Cantilever:
F
1200 kHz
C
85 N/m
L
65 µm
HQ:XSC11/Al BS
HQ:XSC11/Al BS
AFM Probe with 4 Different Cantilevers for Various Applications
Coating: Reflective Aluminum
Tip Shape: Rotated
AFM Cantilevers: 4
1
2
3
4
F
15 kHz
80 kHz
155 kHz
350 kHz
C
0.2 N/m
2.7 N/m
7 N/m
42 N/m
L
500 µm
210 µm
150 µm
100 µm
HQ:NSC36/Cr-Au BS
HQ:NSC36/Cr-Au BS
AFM Probe with 3 Different Gold Coated Force Modulation Mode AFM Cantilevers
Coating: Reflective Gold
Tip Shape: Rotated
AFM Cantilevers: 3
1
2
3
F
90 kHz
130 kHz
65 kHz
C
1 N/m
2 N/m
0.6 N/m
L
110 µm
90 µm
130 µm
HQ:NSC19/Al BS
HQ:NSC19/Al BS
Standard Force Modulation AFM Probe
Coating: Reflective Aluminum
Tip Shape: Rotated
AFM Cantilever:
F
65 kHz
C
0.5 N/m
L
125 µm
PNP-TRS
PNP-TRS

Silicon Nitride AFM Probe Single Cantilever Compatible with ScanAsyst®** Mode

Coating: Reflective Gold
Tip Shape: Pyramid
AFM Cantilever:
F
67 kHz
C
0.32 N/m
L
100 µm
All-In-One-Al
All-In-One-Al
AFM Probe with 4 Different AFM Cantilevers for Various Applications
Coating: Reflective Aluminum
Tip Shape: Rotated
AFM Cantilevers: 4
1
2
3
4
F
15 kHz
80 kHz
150 kHz
350 kHz
C
0.2 N/m
2.7 N/m
7.4 N/m
40 N/m
L
500 µm
210 µm
150 µm
100 µm
top value
240AC-NG
240AC-NG
Gold Coated Force Modulation AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating: Reflective Gold
Tip Shape: Optimized Positioning
AFM Cantilever:
F
70 kHz
C
2 N/m
L
240 µm
HQ:NSC15/Cr-Au BS
HQ:NSC15/Cr-Au BS
Gold Coated Tapping Mode AFM Probe
Coating: Reflective Gold
Tip Shape: Rotated
AFM Cantilever:
F
325 kHz
C
40 N/m
L
125 µm
HQ:NSC16/Cr-Au BS
HQ:NSC16/Cr-Au BS
Gold Coated Tapping Mode AFM Probe with Long AFM Cantilever
Coating: Reflective Gold
Tip Shape: Rotated
AFM Cantilever:
F
190 kHz
C
45 N/m
L
225 µm
Tap300GD-G
Tap300GD-G
Gold Coated Tapping Mode AFM Probe
Coating: Reflective Gold
Tip Shape: Rotated
AFM Cantilever:
F
300 kHz
C
40 N/m
L
125 µm
PPP-CONTSC
PPP-CONTSC
Contact Mode AFM Probe with Short AFM Cantilever
Coating: none
Tip Shape: Standard
AFM Cantilever:
F
25 kHz
C
0.2 N/m
L
225 µm
PPP-NCH
PPP-NCH
Standard Tapping Mode AFM Probe
Coating: none
Tip Shape: Standard
AFM Cantilever:
F
330 kHz
C
42 N/m
L
125 µm
PPP-NCL
PPP-NCL
Tapping Mode AFM Probe, Long AFM Cantilever
Coating: none
Tip Shape: Standard
AFM Cantilever:
F
190 kHz
C
48 N/m
L
225 µm
NCH
NCH
Standard Tapping Mode AFM Probe
Coating: none
Tip Shape: Standard
AFM Cantilever:
F
320 kHz
C
42 N/m
L
125 µm
14