Trapezoidal Cross Section AFM Cantilevers (tip on narrow flank)

Sort by:
328 results
HQ:NSC14/Cr-Au
HQ:NSC14/Cr-Au
Gold Coated Soft Tapping Mode AFM Probe
Coating: Gold Overall
Tip Shape: Rotated
AFM Cantilever:
F
160 kHz
C
5 N/m
L
125 µm
HQ:NSC15/Cr-Au
HQ:NSC15/Cr-Au
Gold Coated Tapping Mode AFM Probe
Coating: Gold Overall
Tip Shape: Rotated
AFM Cantilever:
F
325 kHz
C
40 N/m
L
125 µm
HQ:NSC16/Cr-Au
HQ:NSC16/Cr-Au
Gold Coated Tapping Mode AFM Probe with Long AFM Cantilever
Coating: Gold Overall
Tip Shape: Rotated
AFM Cantilever:
F
190 kHz
C
45 N/m
L
225 µm
HQ:CSC38/Cr-Au
HQ:CSC38/Cr-Au
AFM Probe with 3 Different Gold Coated Contact Mode AFM Cantilevers
Coating: Gold Overall
Tip Shape: Rotated
AFM Cantilevers: 3
1
2
3
F
20 kHz
10 kHz
14 kHz
C
0.09 N/m
0.03 N/m
0.05 N/m
L
250 µm
350 µm
300 µm
Tap150GB-G
Tap150GB-G
Gold Coated Soft Tapping Mode AFM Probe
Coating: Gold Overall
Tip Shape: Rotated
AFM Cantilever:
F
150 kHz
C
5 N/m
L
125 µm
SSS-QMFMR
SSS-QMFMR
SuperSharp, Hard Magnetic, Low Momentum MFM AFM Probe with a High Mechanical Q-Factor
Coating: Magnetic
Tip Shape: Supersharp
AFM Cantilever:
F
75 kHz
C
2.8 N/m
L
225 µm
PPP-LM-MFMR
PPP-LM-MFMR
Hard Magnetic, Low Momentum MFM AFM Probe
Coating: Magnetic
Tip Shape: Standard
AFM Cantilever:
F
75 kHz
C
2.8 N/m
L
225 µm
PPP-LC-MFMR
PPP-LC-MFMR
Soft Magnetic, Medium Momentum MFM AFM Probe
Coating: Magnetic
Tip Shape: Standard
AFM Cantilever:
F
75 kHz
C
2.8 N/m
L
225 µm
PPP-QLC-MFMR
PPP-QLC-MFMR
Soft Magnetic, Medium Momentum MFM AFM Probe with a High Mechanical Q-Factor
Coating: Magnetic
Tip Shape: Standard
AFM Cantilever:
F
75 kHz
C
2.8 N/m
L
225 µm
best of the best
TL-CONT
TL-CONT
Tipless Contact Mode AFM Cantilever
Coating: none
Tip Shape: Tipless
AFM Cantilever:
F
13 kHz
C
0.2 N/m
L
450 µm
TL-FM
TL-FM
Tipless Force Modulation AFM Cantilever
Coating: none
Tip Shape: Tipless
AFM Cantilever:
F
75 kHz
C
2.8 N/m
L
225 µm
TL-NCH
TL-NCH
Tipless Tapping Mode AFM Cantilever
Coating: none
Tip Shape: Tipless
AFM Cantilever:
F
330 kHz
C
42 N/m
L
125 µm
TL-NCL
TL-NCL
Tipless, Long Tapping Mode AFM Cantilever
Coating: none
Tip Shape: Tipless
AFM Cantilever:
F
190 kHz
C
48 N/m
L
225 µm
the industry standard
ARROW-TL1
ARROW-TL1
Tipless AFM Cantilever for Special Applications
Coating: none
Tip Shape: Tipless
AFM Cantilever:
F
6 kHz
C
0.03 N/m
L
500 µm
ARROW-TL2
ARROW-TL2
Tipless AFM Cantilever Array for Special Applications
Coating: none
Tip Shape: Tipless
AFM Cantilevers: 2
1
F
6 kHz
C
0.03 N/m
L
500 µm
ARROW-TL8
ARROW-TL8
Tipless AFM Cantilever Array for Special Applications
Coating: none
Tip Shape: Tipless
AFM Cantilevers: 8
1
F
6 kHz
C
0.03 N/m
L
500 µm
HQ:NSC35/tipless/No Al
HQ:NSC35/tipless/No Al
Tipless AFM Probe with 3 Different Tapping Mode AFM Cantilevers
Coating: none
Tip Shape: Tipless
AFM Cantilevers: 3
1
2
3
F
205 kHz
300 kHz
150 kHz
C
8.9 N/m
16 N/m
5.4 N/m
L
110 µm
90 µm
130 µm
HQ:NSC36/tipless/No Al
HQ:NSC36/tipless/No Al
Tipless AFM Probe with 3 Different Force Modulation AFM Cantilevers
Coating: none
Tip Shape: Tipless
AFM Cantilevers: 3
1
2
3
F
90 kHz
130 kHz
65 kHz
C
1 N/m
2 N/m
0.6 N/m
L
110 µm
90 µm
130 µm
HQ:CSC37/tipless/No Al
HQ:CSC37/tipless/No Al
Tipless AFM Probe with 3 Different Contact Mode AFM Cantilevers
Coating: none
Tip Shape: Tipless
AFM Cantilevers: 3
1
2
3
F
40 kHz
20 kHz
30 kHz
C
0.8 N/m
0.3 N/m
0.4 N/m
L
250 µm
350 µm
300 µm
top value
HQ:CSC38/tipless/No Al
HQ:CSC38/tipless/No Al
Tipless AFM Probe with 3 Different Contact Mode AFM Cantilevers
Coating: none
Tip Shape: Tipless
AFM Cantilevers: 3
1
2
3
F
20 kHz
10 kHz
14 kHz
C
0.09 N/m
0.03 N/m
0.05 N/m
L
250 µm
350 µm
300 µm
17