Trapezoidal Cross Section AFM Cantilevers (tip on narrow flank)

Sort by:
328 results
PPP-FMAu
PPP-FMAu
Gold Coated Force Modulation AFM Probe
Coating: Gold Overall
Tip Shape: Standard
AFM Cantilever:
F
75 kHz
C
2.8 N/m
L
225 µm
HQ:NSC18/Cr-Au
HQ:NSC18/Cr-Au
Gold Coated Force Modulation AFM Probe
Coating: Gold Overall
Tip Shape: Rotated
AFM Cantilever:
F
75 kHz
C
2.8 N/m
L
225 µm
HQ:NSC19/Cr-Au
HQ:NSC19/Cr-Au
Gold Coated Force Modulation AFM Probe
Coating: Gold Overall
Tip Shape: Rotated
AFM Cantilever:
F
65 kHz
C
0.5 N/m
L
125 µm
HQ:NSC35/Cr-Au
HQ:NSC35/Cr-Au
AFM Probe with 3 Different Gold Coated Tapping Mode AFM Cantilevers
Coating: Gold Overall
Tip Shape: Rotated
AFM Cantilevers: 3
1
2
3
F
205 kHz
300 kHz
150 kHz
C
8.9 N/m
16 N/m
5.4 N/m
L
110 µm
90 µm
130 µm
HQ:NSC36/Cr-Au
HQ:NSC36/Cr-Au
AFM Probe with 3 Different Gold Coated Force Modulation Mode AFM Cantilevers
Coating: Gold Overall
Tip Shape: Rotated
AFM Cantilevers: 3
1
2
3
F
90 kHz
130 kHz
65 kHz
C
1 N/m
2 N/m
0.6 N/m
L
110 µm
90 µm
130 µm
Multi75GB-G
Multi75GB-G
Gold Coated Force Modulation AFM Probe
Coating: Gold Overall
Tip Shape: Rotated
AFM Cantilever:
F
75 kHz
C
3 N/m
L
225 µm
M-CIS
M-CIS
EBD AFM whisker for non-contact AFM microlens contact image sensor (CIS) inspection
Coating: Reflective Aluminum
Tip Shape: High-Aspect-Ratio,Cone Shaped,EBD
AFM Cantilever:
F
320 kHz
C
40 N/m
L
120 µm
EBD-HAR
EBD-HAR
Universal high-aspect ratio EBD AFM whisker for enhanced resolution, imaging stability and AFM tip lifetime
Coating: none
Tip Shape: High-Aspect-Ratio,Cone Shaped,EBD
AFM Cantilever:
F
330 kHz
C
40 N/m
L
125 µm
EBD-AR20T
EBD-AR20T
High-aspect ratio, tilt compensated EBD AFM whisker for automated non-contact AFM
Coating: none
Tip Shape: High-Aspect-Ratio,Cone Shaped,EBD
AFM Cantilever:
F
330 kHz
C
40 N/m
L
125 µm
M1-HAR
M1-HAR
High-aspect ratio, tilt compensated EBD AFM whisker for automated non-contact AFM
Coating: none
Tip Shape: High-Aspect-Ratio,Cone Shaped,EBD
AFM Cantilever:
F
320 kHz
C
40 N/m
L
120 µm
PPP-CONTAu
PPP-CONTAu
Gold Coated Contact Mode AFM Probe
Coating: Gold Overall
Tip Shape: Standard
AFM Cantilever:
F
13 kHz
C
0.2 N/m
L
450 µm
PPP-NCSTAu
PPP-NCSTAu
Gold Coated Soft Tapping Mode AFM Probe
Coating: Gold Overall
Tip Shape: Standard
AFM Cantilever:
F
160 kHz
C
7.4 N/m
L
150 µm
ContGB-G
ContGB-G
Gold Coated Contact Mode AFM Probe
Coating: Gold Overall
Tip Shape: Rotated
AFM Cantilever:
F
13 kHz
C
0.2 N/m
L
450 µm
HQ:CSC17/Cr-Au
HQ:CSC17/Cr-Au
Gold Coated Contact Mode AFM Probe
Coating: Gold Overall
Tip Shape: Rotated
AFM Cantilever:
F
13 kHz
C
0.18 N/m
L
450 µm
HQ:CSC37/Cr-Au
HQ:CSC37/Cr-Au
AFM Probe with 3 Different Gold Coated Contact Mode AFM Cantilevers
Coating: Gold Overall
Tip Shape: Rotated
AFM Cantilevers: 3
1
2
3
F
40 kHz
20 kHz
30 kHz
C
0.8 N/m
0.3 N/m
0.4 N/m
L
250 µm
350 µm
300 µm
PPP-CONTSCAu
PPP-CONTSCAu
Gold Coated Contact Mode AFM Probe with Short AFM Cantilever
Coating: Gold Overall
Tip Shape: Standard
AFM Cantilever:
F
25 kHz
C
0.2 N/m
L
225 µm
PPP-NCHAu
PPP-NCHAu
Gold Coated Tapping Mode AFM Probe
Coating: Gold Overall
Tip Shape: Standard
AFM Cantilever:
F
330 kHz
C
42 N/m
L
125 µm
PPP-NCLAu
PPP-NCLAu
Gold Coated Tapping Mode AFM Probe with Long AFM Cantilever
Coating: Gold Overall
Tip Shape: Standard
AFM Cantilever:
F
190 kHz
C
48 N/m
L
225 µm
Tap300GB-G
Tap300GB-G
Gold Coated Tapping Mode AFM Probe
Coating: Gold Overall
Tip Shape: Rotated
AFM Cantilever:
F
300 kHz
C
40 N/m
L
125 µm
Tap190GB-G
Tap190GB-G
Gold Coated Tapping Mode AFM Probe with Long AFM Cantilever
Coating: Gold Overall
Tip Shape: Rotated
AFM Cantilever:
F
190 kHz
C
48 N/m
L
225 µm
17