NanoAndMore USA does not ship to your country
Trapezoidal Cross Section AFM Cantilevers (tip on narrow flank)
Sort by:
328 results
best of the best


PPP-NCHR
Standard Tapping Mode AFM Probe
Coating:
Reflective Aluminum
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
330 kHz
C
42 N/m
L
125 µm
New


PPP-NCR
Standard Tapping Mode AFM Probe with AC160 mechanical properties
Coating:
Reflective Aluminum
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
300 kHz
C
26 N/m
L
125 µm
the industry standard


NCHR
Standard Tapping Mode AFM Probe
Coating:
Reflective Aluminum
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
320 kHz
C
42 N/m
L
125 µm


TESPA
Standard Tapping Mode AFM Probe
Coating:
Reflective Aluminum
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
320 kHz
C
42 N/m
L
125 µm


ARROW-NCR
Tapping Mode AFM Probe with Tip at the Very End of the Cantilever
Coating:
Reflective Aluminum
Tip Shape: Arrow
Tip Shape: Arrow
AFM Cantilever:
F
285 kHz
C
42 N/m
L
160 µm
top value


HQ:NSC15/Al BS
Standard Tapping Mode AFM Probe
Coating:
Reflective Aluminum
Tip Shape: Rotated
Tip Shape: Rotated
AFM Cantilever:
F
325 kHz
C
40 N/m
L
125 µm
best bang for your buck


Tap300Al-G
Standard Tapping Mode AFM Probe
Coating:
Reflective Aluminum
Tip Shape: Rotated
Tip Shape: Rotated
AFM Cantilever:
F
300 kHz
C
40 N/m
L
125 µm


PPP-NCLR
Tapping Mode AFM Probe, Long AFM Cantilever
Coating:
Reflective Aluminum
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
190 kHz
C
48 N/m
L
225 µm


NCLR
Tapping Mode AFM Probe, Long Cantilever
Coating:
Reflective Aluminum
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
190 kHz
C
48 N/m
L
225 µm


HQ:NSC16/Al BS
Tapping Mode AFM Probe with Long AFM Cantilever
Coating:
Reflective Aluminum
Tip Shape: Rotated
Tip Shape: Rotated
AFM Cantilever:
F
190 kHz
C
45 N/m
L
225 µm


Tap190Al-G
Tapping Mode AFM Probe with Long AFM Cantilever
Coating:
Reflective Aluminum
Tip Shape: Rotated
Tip Shape: Rotated
AFM Cantilever:
F
190 kHz
C
48 N/m
L
225 µm


EBD-NCH
Universal EBD AFM whisker for enhanced resolution, imaging stability and AFM tip lifetime
Coating:
none
Tip Shape: Cone Shaped,EBD
Tip Shape: Cone Shaped,EBD
AFM Cantilever:
F
330 kHz
C
40 N/m
L
125 µm
best of the best


PPP-QNCHR
Tapping Mode AFM Probe, for UHV Conditions
Coating:
Reflective Aluminum
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
330 kHz
C
42 N/m
L
125 µm


PPP-RT-NCHR
Standard Tapping Mode AFM Probe
Coating:
Reflective Aluminum
Tip Shape: Rotated
Tip Shape: Rotated
AFM Cantilever:
F
330 kHz
C
42 N/m
L
125 µm
best of the best


PPP-NCSTR
Soft Tapping Mode AFM Probe
Coating:
Reflective Aluminum
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
160 kHz
C
7.4 N/m
L
150 µm
the industry standard


NCSTR
Soft Tapping Mode AFM Probe
Coating:
Reflective Aluminum
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
160 kHz
C
7.4 N/m
L
150 µm
top value


HQ:NSC14/Al BS
Soft Tapping Mode AFM Probe
Coating:
Reflective Aluminum
Tip Shape: Rotated
Tip Shape: Rotated
AFM Cantilever:
F
160 kHz
C
5 N/m
L
125 µm


HQ:NSC35/Al BS
AFM Probe with 3 Different Tapping Mode AFM Cantilevers
Coating:
Reflective Aluminum
Tip Shape: Rotated
Tip Shape: Rotated
AFM Cantilevers: 3
1
2
3
F
205 kHz
300 kHz
150 kHz
C
8.9 N/m
16 N/m
5.4 N/m
L
110 µm
90 µm
130 µm
best bang for your buck


Tap150Al-G
Soft Tapping Mode AFM Probe
Coating:
Reflective Aluminum
Tip Shape: Rotated
Tip Shape: Rotated
AFM Cantilever:
F
150 kHz
C
5 N/m
L
125 µm


PPP-NCST
Soft Tapping Mode AFM Probe
Coating:
none
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
160 kHz
C
7.4 N/m
L
150 µm