NanoAndMore GmbH does not ship to your country
Uncoated AFM Tips
AFM probes with uncoated AFM tips
Sort by:
265 results


55AC-NG
Gold Coated Ultra High Frequency AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating:
Reflective Gold
Tip Shape: Optimized Positioning
Tip Shape: Optimized Positioning
AFM Cantilever:
F
1200 kHz
C
85 N/m
L
65 µm
top value


55AC-NA
Ultra High Frequency AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating:
Reflective Aluminum
Tip Shape: Optimized Positioning
Tip Shape: Optimized Positioning
AFM Cantilever:
F
1200 kHz
C
85 N/m
L
65 µm


55AC-NN
Ultra High Frequency AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating:
none
Tip Shape: Optimized Positioning
Tip Shape: Optimized Positioning
AFM Cantilever:
F
1200 kHz
C
85 N/m
L
65 µm


HQ:XSC11/Al BS
AFM Probe with 4 Different Cantilevers for Various Applications
Coating:
Reflective Aluminum
Tip Shape: Rotated
Tip Shape: Rotated
AFM Cantilevers: 4
1
2
3
4
F
15 kHz
80 kHz
155 kHz
350 kHz
C
0.2 N/m
2.7 N/m
7 N/m
42 N/m
L
500 µm
210 µm
150 µm
100 µm


HQ:NSC36/Cr-Au BS
AFM Probe with 3 Different Gold Coated Force Modulation Mode AFM Cantilevers
Coating:
Reflective Gold
Tip Shape: Rotated
Tip Shape: Rotated
AFM Cantilevers: 3
1
2
3
F
90 kHz
130 kHz
65 kHz
C
1 N/m
2 N/m
0.6 N/m
L
110 µm
90 µm
130 µm


HQ:NSC19/Al BS
Standard Force Modulation AFM Probe
Coating:
Reflective Aluminum
Tip Shape: Rotated
Tip Shape: Rotated
AFM Cantilever:
F
65 kHz
C
0.5 N/m
L
125 µm


PNP-TRS
Silicon Nitride AFM Probe Single Cantilever Compatible with ScanAsyst®** Mode
Coating:
Reflective Gold
Tip Shape: Pyramid
Tip Shape: Pyramid
AFM Cantilever:
F
67 kHz
C
0.32 N/m
L
100 µm


All-In-One-Al
AFM Probe with 4 Different AFM Cantilevers for Various Applications
Coating:
Reflective Aluminum
Tip Shape: Rotated
Tip Shape: Rotated
AFM Cantilevers: 4
1
2
3
4
F
15 kHz
80 kHz
150 kHz
350 kHz
C
0.2 N/m
2.7 N/m
7.4 N/m
40 N/m
L
500 µm
210 µm
150 µm
100 µm
top value


240AC-NG
Gold Coated Force Modulation AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating:
Reflective Gold
Tip Shape: Optimized Positioning
Tip Shape: Optimized Positioning
AFM Cantilever:
F
70 kHz
C
2 N/m
L
240 µm


HQ:NSC15/Cr-Au BS
Gold Coated Tapping Mode AFM Probe
Coating:
Reflective Gold
Tip Shape: Rotated
Tip Shape: Rotated
AFM Cantilever:
F
325 kHz
C
40 N/m
L
125 µm


HQ:NSC16/Cr-Au BS
Gold Coated Tapping Mode AFM Probe with Long AFM Cantilever
Coating:
Reflective Gold
Tip Shape: Rotated
Tip Shape: Rotated
AFM Cantilever:
F
190 kHz
C
45 N/m
L
225 µm


Tap300GD-G
Gold Coated Tapping Mode AFM Probe
Coating:
Reflective Gold
Tip Shape: Rotated
Tip Shape: Rotated
AFM Cantilever:
F
300 kHz
C
40 N/m
L
125 µm


PPP-CONTSC
Contact Mode AFM Probe with Short AFM Cantilever
Coating:
none
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
25 kHz
C
0.2 N/m
L
225 µm


PPP-NCH
Standard Tapping Mode AFM Probe
Coating:
none
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
330 kHz
C
42 N/m
L
125 µm


PPP-NCL
Tapping Mode AFM Probe, Long AFM Cantilever
Coating:
none
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
190 kHz
C
48 N/m
L
225 µm


NCH
Standard Tapping Mode AFM Probe
Coating:
none
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
320 kHz
C
42 N/m
L
125 µm


TESP
Standard Tapping Mode AFM Probe
Coating:
none
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
320 kHz
C
42 N/m
L
125 µm


ARROW-NC
Tapping Mode AFM Probe with Tip at the Very End of the Cantilever
Coating:
none
Tip Shape: Arrow
Tip Shape: Arrow
AFM Cantilever:
F
285 kHz
C
42 N/m
L
160 µm


LTESP
Tapping Mode AFM Probe, Long Cantilever
Coating:
none
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
190 kHz
C
48 N/m
L
225 µm


NCL
Tapping Mode AFM Probe, Long Cantilever
Coating:
none
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
190 kHz
C
48 N/m
L
225 µm