NanoAndMore USA does not ship to your country
Rectangular / Diving Board AFM Cantilevers
AFM probes with rectangular / diving board AFM cantilevers
Sort by:
397 results
Multi75DLC
Diamond-Like-Carbon Coated Force Modulation AFM Probe
Coating:
Hard Diamond-Like-Carbon
Tip Shape: Rotated
Tip Shape: Rotated
AFM Cantilever:
F
75 kHz
C
3 N/m
L
225 µm
PPP-NCHAuD
Gold Coated Tapping Mode AFM Probe
Coating:
Reflective Gold
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
330 kHz
C
42 N/m
L
125 µm
PPP-RT-FMR
Standard Force Modulation AFM Probe
Coating:
Reflective Aluminum
Tip Shape: Rotated
Tip Shape: Rotated
AFM Cantilever:
F
75 kHz
C
2.8 N/m
L
225 µm
PPP-QFMR
Force Modulation AFM Probe, for UHV Conditions
Coating:
Reflective Aluminum
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
75 kHz
C
2.8 N/m
L
225 µm
best of the best
PPP-CONTR
Standard Contact Mode AFM Probe
Coating:
Reflective Aluminum
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
13 kHz
C
0.2 N/m
L
450 µm
ATEC-CONT
Contact Mode AFM Probe with REAL Tip Visibility
Coating:
none
Tip Shape: Visible
Tip Shape: Visible
AFM Cantilever:
F
15 kHz
C
0.2 N/m
L
450 µm
best of the best
PPP-LFMR
Standard Lateral Force Mode AFM Probes
Coating:
Reflective Aluminum
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
23 kHz
C
0.2 N/m
L
225 µm
the industry standard
CONTR
Standard Contact Mode AFM Probe
Coating:
Reflective Aluminum
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
13 kHz
C
0.2 N/m
L
450 µm
ARROW-CONTR
Contact Mode AFM Probe with Tip at the Very End of the Cantilever
Coating:
Reflective Aluminum
Tip Shape: Arrow
Tip Shape: Arrow
AFM Cantilever:
F
14 kHz
C
0.2 N/m
L
450 µm
top value
HQ:CSC17/Al BS
Standard Contact Mode AFM Probe
Coating:
Reflective Aluminum
Tip Shape: Rotated
Tip Shape: Rotated
AFM Cantilever:
F
13 kHz
C
0.18 N/m
L
450 µm
best bang for your buck
ContAl-G
Standard Contact Mode AFM Probe
Coating:
Reflective Aluminum
Tip Shape: Rotated
Tip Shape: Rotated
AFM Cantilever:
F
13 kHz
C
0.2 N/m
L
450 µm
best of the best
CDT-FMR
Diamond Coated, Conductive Force Modulation AFM Probe
Coating:
Diamond,Conductive Diamond
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
105 kHz
C
6.2 N/m
L
225 µm
best of the best
PPP-EFM
Electrical, Force Modulation AFM Probe
Coating:
Electrically Conductive
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
75 kHz
C
2.8 N/m
L
225 µm
ATEC-EFM
Electrical, Force Modulation AFM Probe with REAL Tip Visibility
Coating:
Electrically Conductive
Tip Shape: Visible
Tip Shape: Visible
AFM Cantilever:
F
85 kHz
C
2.8 N/m
L
240 µm
the industry standard
NW-CDT-FMR
Diamond Coated, Conductive Force Modulation AFM Probe
Coating:
Diamond,Conductive Diamond
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
105 kHz
C
6.2 N/m
L
225 µm
ARROW-EFM
Electrical, Force Modulation AFM Probe with Tip at the Very End of the Cantilever
Coating:
Electrically Conductive
Tip Shape: Arrow
Tip Shape: Arrow
AFM Cantilever:
F
75 kHz
C
2.8 N/m
L
240 µm
the industry standard
EFM
Electrical, Force Modulation AFM Probe
Coating:
Electrically Conductive
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
75 kHz
C
2.8 N/m
L
225 µm
top value
HQ:NSC18/Pt
Electrical, Force Modulation AFM Probe
Coating:
Electrically Conductive
Tip Shape: Rotated
Tip Shape: Rotated
AFM Cantilever:
F
75 kHz
C
2.8 N/m
L
225 µm
top value
240AC-PP
Electrical, Force Modulation AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating:
Electrically Conductive
Tip Shape: Optimized Positioning
Tip Shape: Optimized Positioning
AFM Cantilever:
F
70 kHz
C
2 N/m
L
240 µm
New
OMCL-AC240TM
Electrical, Force Modulation AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating:
Electrically Conductive
Tip Shape: Optimized Positioning
Tip Shape: Optimized Positioning
AFM Cantilever:
F
70 kHz
C
2 N/m
L
240 µm