NanoAndMore USA does not ship to your country
3-sided Sharpened Pyramidal AFM Tips
AFM probes with 3-sided sharpened pyramidal active part of the AFM tips
Sort by:
242 results


ElectriTap150-G
Electrical, Soft Tapping Mode AFM Probe
Coating:
Electrically Conductive
Tip Shape: Rotated
Tip Shape: Rotated
AFM Cantilever:
F
150 kHz
C
5 N/m
L
125 µm


PPP-CONTPt
Electrical, Contact Mode AFM Probe
Coating:
Electrically Conductive
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
13 kHz
C
0.2 N/m
L
450 µm


PPP-CONTSCPt
Electrical, Contact Mode AFM Probe with Short AFM Cantilever
Coating:
Electrically Conductive
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
25 kHz
C
0.2 N/m
L
225 µm


ATEC-CONTPt
Electrical, Contact Mode AFM Probe with REAL Tip Visibility
Coating:
Electrically Conductive
Tip Shape: Visible
Tip Shape: Visible
AFM Cantilever:
F
15 kHz
C
0.2 N/m
L
450 µm


ARROW-CONTPt
Electrical, Contact Mode AFM Probe with Tip at the Very End of the Cantilever
Coating:
Electrically Conductive
Tip Shape: Arrow
Tip Shape: Arrow
AFM Cantilever:
F
14 kHz
C
0.2 N/m
L
450 µm


CONTPt
Electrical, Contact Mode AFM Probe
Coating:
Electrically Conductive
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
13 kHz
C
0.2 N/m
L
450 µm


ElectriCont-G
Electrical, Contact Mode AFM Probe
Coating:
Electrically Conductive
Tip Shape: Rotated
Tip Shape: Rotated
AFM Cantilever:
F
13 kHz
C
0.2 N/m
L
450 µm


HQ:CSC37/Pt
AFM Probe with 3 Different Electrical, Contact Mode AFM Cantilevers
Coating:
Electrically Conductive
Tip Shape: Rotated
Tip Shape: Rotated
AFM Cantilevers: 3
1
2
3
F
40 kHz
20 kHz
30 kHz
C
0.8 N/m
0.3 N/m
0.4 N/m
L
250 µm
350 µm
300 µm


SCM-PIC
Electrical, Contact Mode AFM Probe
Coating:
Electrically Conductive
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
13 kHz
C
0.2 N/m
L
450 µm


SCM-PIT
Electrical, Force Modulation AFM Probe
Coating:
Electrically Conductive
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
75 kHz
C
2.8 N/m
L
225 µm


ATEC-FMAu
Gold Coated Force Modulation AFM Probe with REAL Tip Visibility
Coating:
Gold Overall
Tip Shape: Visible
Tip Shape: Visible
AFM Cantilever:
F
85 kHz
C
2.8 N/m
L
240 µm


HQ:CSC17/Pt
Electrical, Contact Mode AFM Probe
Coating:
Electrically Conductive
Tip Shape: Rotated
Tip Shape: Rotated
AFM Cantilever:
F
13 kHz
C
0.18 N/m
L
450 µm


PPP-FMAu
Gold Coated Force Modulation AFM Probe
Coating:
Gold Overall
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
75 kHz
C
2.8 N/m
L
225 µm


HQ:NSC18/Cr-Au
Gold Coated Force Modulation AFM Probe
Coating:
Gold Overall
Tip Shape: Rotated
Tip Shape: Rotated
AFM Cantilever:
F
75 kHz
C
2.8 N/m
L
225 µm


HQ:NSC19/Cr-Au
Gold Coated Force Modulation AFM Probe
Coating:
Gold Overall
Tip Shape: Rotated
Tip Shape: Rotated
AFM Cantilever:
F
65 kHz
C
0.5 N/m
L
125 µm


HQ:NSC35/Cr-Au
AFM Probe with 3 Different Gold Coated Tapping Mode AFM Cantilevers
Coating:
Gold Overall
Tip Shape: Rotated
Tip Shape: Rotated
AFM Cantilevers: 3
1
2
3
F
205 kHz
300 kHz
150 kHz
C
8.9 N/m
16 N/m
5.4 N/m
L
110 µm
90 µm
130 µm


HQ:NSC36/Cr-Au
AFM Probe with 3 Different Gold Coated Force Modulation Mode AFM Cantilevers
Coating:
Gold Overall
Tip Shape: Rotated
Tip Shape: Rotated
AFM Cantilevers: 3
1
2
3
F
90 kHz
130 kHz
65 kHz
C
1 N/m
2 N/m
0.6 N/m
L
110 µm
90 µm
130 µm


3XC-GG
AFM Probe with 3 Different Gold Coated AFM Cantilevers for Various Applications and AFM Tips at the Very End of the AFM Cantilevers
Coating:
Gold Overall
Tip Shape: Optimized Positioning
Tip Shape: Optimized Positioning
AFM Cantilevers: 3
1
2
3
F
17 kHz
150 kHz
75 kHz
C
0.3 N/m
9 N/m
2.5 N/m
L
500 µm
175 µm
240 µm


4XC-GG
AFM Probe with 4 Different Gold Coated AFM Cantilevers with AFM Tips at the Very End of the AFM Cantilevers
Coating:
Gold Overall
Tip Shape: Optimized Positioning
Tip Shape: Optimized Positioning
AFM Cantilevers: 4
1
2
3
4
F
17 kHz
75 kHz
150 kHz
1200 kHz
C
0.3 N/m
2.5 N/m
9 N/m
100 N/m
L
500 µm
240 µm
175 µm
65 µm


240AC-GG
Gold Coated Force Modulation AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating:
Gold Overall
Tip Shape: Optimized Positioning
Tip Shape: Optimized Positioning
AFM Cantilever:
F
70 kHz
C
2 N/m
L
240 µm