1 Single AFM Cantilever per AFM Probe

AFM probes with one single AFM cantilever
Sort by:
340 results
top value
160AC-FG
160AC-FG
High Aspect Ratio, Tapping Mode AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating: Reflective Gold
Tip Shape: High-Aspect-Ratio
AFM Cantilever:
F
300 kHz
C
26 N/m
L
160 µm
New
240AC-FG
240AC-FG
High Aspect Ratio, Force Modulation AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating: Reflective Gold
Tip Shape: High-Aspect-Ratio
AFM Cantilever:
F
70 kHz
C
2 N/m
L
240 µm
EBD-AR15T
EBD-AR15T
High-aspect ratio, tilt compensated EBD AFM whisker for automated non-contact AFM
Coating: none
Tip Shape: High-Aspect-Ratio,Cone Shaped,EBD
AFM Cantilever:
F
330 kHz
C
40 N/m
L
125 µm
AR10-NCHR
AR10-NCHR
High-Aspect-Ratio, Tapping Mode AFM Probe
Coating: Reflective Aluminum
Tip Shape: High-Aspect-Ratio
AFM Cantilever:
F
330 kHz
C
42 N/m
L
125 µm
AR5-NCHR
AR5-NCHR
High-Aspect-Ratio, Tapping Mode AFM Probe
Coating: Reflective Aluminum
Tip Shape: High-Aspect-Ratio
AFM Cantilever:
F
330 kHz
C
42 N/m
L
125 µm
AR5-NCH
AR5-NCH
High-Aspect-Ratio, Tapping Mode AFM Probe
Coating: none
Tip Shape: High-Aspect-Ratio
AFM Cantilever:
F
330 kHz
C
42 N/m
L
125 µm
NW-AR10-NCHR
NW-AR10-NCHR
High-Aspect-Ratio, Tapping Mode AFM Probe
Coating: Reflective Aluminum
Tip Shape: High-Aspect-Ratio
AFM Cantilever:
F
320 kHz
C
42 N/m
L
125 µm
NW-AR5-NCHR
NW-AR5-NCHR
High-Aspect-Ratio, Tapping Mode AFM Probe
Coating: Reflective Aluminum
Tip Shape: High-Aspect-Ratio
AFM Cantilever:
F
320 kHz
C
42 N/m
L
125 µm
AR5-NCLR
AR5-NCLR
High-Aspect-Ratio, Tapping Mode AFM Probe with Long AFM Cantilever
Coating: Reflective Aluminum
Tip Shape: High-Aspect-Ratio
AFM Cantilever:
F
190 kHz
C
48 N/m
L
225 µm
NW-AR5-NCLR
NW-AR5-NCLR
High-Aspect-Ratio, Tapping Mode AFM Probe with Long Cantilever
Coating: Reflective Aluminum
Tip Shape: High-Aspect-Ratio
AFM Cantilever:
F
190 kHz
C
48 N/m
L
225 µm
CDT-NCHR
CDT-NCHR
Diamond Coated, Conductive Tapping Mode AFM Probe
Coating: Diamond,Conductive Diamond
Tip Shape: Standard
AFM Cantilever:
F
400 kHz
C
80 N/m
L
125 µm
CDT-NCLR
CDT-NCLR
Diamond Coated, Conductive Tapping Mode AFM Probe with Long AFM Cantilever
Coating: Diamond,Conductive Diamond
Tip Shape: Standard
AFM Cantilever:
F
210 kHz
C
72 N/m
L
225 µm
NW-CDT-NCHR
NW-CDT-NCHR

Diamond Coated, Conductive Tapping Mode AFM Probe

Coating: Diamond,Conductive Diamond
Tip Shape: Standard
AFM Cantilever:
F
400 kHz
C
80 N/m
L
125 µm
NW-CDT-NCLR
NW-CDT-NCLR

Diamond Coated, Conductive Tapping Mode AFM Probe with Long Cantilever

Coating: Diamond,Conductive Diamond
Tip Shape: Standard
AFM Cantilever:
F
210 kHz
C
72 N/m
L
225 µm
PPP-NCHPt
PPP-NCHPt
Electrical, Tapping Mode AFM Probe
Coating: Electrically Conductive
Tip Shape: Standard
AFM Cantilever:
F
330 kHz
C
42 N/m
L
125 µm
ATEC-NCPt
ATEC-NCPt
Electrical, Tapping Mode AFM Probe with REAL Tip Visibility
Coating: Electrically Conductive
Tip Shape: Visible
AFM Cantilever:
F
335 kHz
C
45 N/m
L
160 µm
PPP-NCSTPt
PPP-NCSTPt
Electrical, Soft Tapping Mode AFM Probe
Coating: Electrically Conductive
Tip Shape: Standard
AFM Cantilever:
F
160 kHz
C
7.4 N/m
L
150 µm
PPP-NCLPt
PPP-NCLPt
Electrical, Tapping Mode AFM Probe with a Long AFM Cantilever
Coating: Electrically Conductive
Tip Shape: Standard
AFM Cantilever:
F
190 kHz
C
48 N/m
L
225 µm
NCHPt
NCHPt
Electrical, Tapping Mode AFM Probe
Coating: Electrically Conductive
Tip Shape: Standard
AFM Cantilever:
F
320 kHz
C
42 N/m
L
125 µm
ARROW-NCPt
ARROW-NCPt
Electrical, Tapping Mode AFM Probe with Tip at the Very End of the Cantilever
Coating: Electrically Conductive
Tip Shape: Arrow
AFM Cantilever:
F
285 kHz
C
42 N/m
L
160 µm
17