NanoAndMore GmbH does not ship to your country
1 Single AFM Cantilever per AFM Probe
AFM probes with one single AFM cantilever
Sort by:
335 results


AR5-NCHR
High-Aspect-Ratio, Tapping Mode AFM Probe
Coating:
Reflective Aluminum
Tip Shape: High-Aspect-Ratio
Tip Shape: High-Aspect-Ratio
AFM Cantilever:
F
330 kHz
C
42 N/m
L
125 µm


AR5-NCH
High-Aspect-Ratio, Tapping Mode AFM Probe
Coating:
none
Tip Shape: High-Aspect-Ratio
Tip Shape: High-Aspect-Ratio
AFM Cantilever:
F
330 kHz
C
42 N/m
L
125 µm


NW-AR10-NCHR
High-Aspect-Ratio, Tapping Mode AFM Probe
Coating:
Reflective Aluminum
Tip Shape: High-Aspect-Ratio
Tip Shape: High-Aspect-Ratio
AFM Cantilever:
F
320 kHz
C
42 N/m
L
125 µm


NW-AR5-NCHR
High-Aspect-Ratio, Tapping Mode AFM Probe
Coating:
Reflective Aluminum
Tip Shape: High-Aspect-Ratio
Tip Shape: High-Aspect-Ratio
AFM Cantilever:
F
320 kHz
C
42 N/m
L
125 µm


AR5-NCLR
High-Aspect-Ratio, Tapping Mode AFM Probe with Long AFM Cantilever
Coating:
Reflective Aluminum
Tip Shape: High-Aspect-Ratio
Tip Shape: High-Aspect-Ratio
AFM Cantilever:
F
190 kHz
C
48 N/m
L
225 µm


NW-AR5-NCLR
High-Aspect-Ratio, Tapping Mode AFM Probe with Long Cantilever
Coating:
Reflective Aluminum
Tip Shape: High-Aspect-Ratio
Tip Shape: High-Aspect-Ratio
AFM Cantilever:
F
190 kHz
C
48 N/m
L
225 µm


CDT-NCHR
Diamond Coated, Conductive Tapping Mode AFM Probe
Coating:
Diamond,Conductive Diamond
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
400 kHz
C
80 N/m
L
125 µm


CDT-NCLR
Diamond Coated, Conductive Tapping Mode AFM Probe with Long AFM Cantilever
Coating:
Diamond,Conductive Diamond
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
210 kHz
C
72 N/m
L
225 µm


NW-CDT-NCHR
Diamond Coated, Conductive Tapping Mode AFM Probe
Coating:
Diamond,Conductive Diamond
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
400 kHz
C
80 N/m
L
125 µm


NW-CDT-NCLR
Diamond Coated, Conductive Tapping Mode AFM Probe with Long Cantilever
Coating:
Diamond,Conductive Diamond
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
210 kHz
C
72 N/m
L
225 µm


PPP-NCHPt
Electrical, Tapping Mode AFM Probe
Coating:
Electrically Conductive
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
330 kHz
C
42 N/m
L
125 µm


ATEC-NCPt
Electrical, Tapping Mode AFM Probe with REAL Tip Visibility
Coating:
Electrically Conductive
Tip Shape: Visible
Tip Shape: Visible
AFM Cantilever:
F
335 kHz
C
45 N/m
L
160 µm


PPP-NCSTPt
Electrical, Soft Tapping Mode AFM Probe
Coating:
Electrically Conductive
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
160 kHz
C
7.4 N/m
L
150 µm


PPP-NCLPt
Electrical, Tapping Mode AFM Probe with a Long AFM Cantilever
Coating:
Electrically Conductive
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
190 kHz
C
48 N/m
L
225 µm


NCHPt
Electrical, Tapping Mode AFM Probe
Coating:
Electrically Conductive
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
320 kHz
C
42 N/m
L
125 µm


ARROW-NCPt
Electrical, Tapping Mode AFM Probe with Tip at the Very End of the Cantilever
Coating:
Electrically Conductive
Tip Shape: Arrow
Tip Shape: Arrow
AFM Cantilever:
F
285 kHz
C
42 N/m
L
160 µm


HQ:NSC15/Pt
Electrical, Tapping Mode AFM Probe
Coating:
Electrically Conductive
Tip Shape: Rotated
Tip Shape: Rotated
AFM Cantilever:
F
325 kHz
C
40 N/m
L
125 µm


NCLPt
Electrical, Tapping Mode AFM Probe with a Long Cantilever
Coating:
Electrically Conductive
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
190 kHz
C
48 N/m
L
225 µm


HQ:NSC16/Pt
Electrical, Tapping Mode AFM Probe with Long AFM Cantilever
Coating:
Electrically Conductive
Tip Shape: Rotated
Tip Shape: Rotated
AFM Cantilever:
F
190 kHz
C
45 N/m
L
225 µm


HQ:NSC14/Pt
Electrical, Soft Tapping Mode AFM Probe
Coating:
Electrically Conductive
Tip Shape: Rotated
Tip Shape: Rotated
AFM Cantilever:
F
160 kHz
C
5 N/m
L
125 µm