Non-Contact / Soft Tapping Mode AFM Probes

AFM probes with medium-soft AFM cantilevers for measuring soft samples in air or vacuum
Sort by:
61 results
best of the best
PPP-NCSTR
PPP-NCSTR
Soft Tapping Mode AFM Probe
Coating: Reflective Aluminum
Tip Shape: Standard
AFM Cantilever:
F
160 kHz
C
7.4 N/m
L
150 µm
the industry standard
NCSTR
NCSTR

Soft Tapping Mode AFM Probe

Coating: Reflective Aluminum
Tip Shape: Standard
AFM Cantilever:
F
160 kHz
C
7.4 N/m
L
150 µm
top value
HQ:NSC14/Al BS
HQ:NSC14/Al BS
Soft Tapping Mode AFM Probe
Coating: Reflective Aluminum
Tip Shape: Rotated
AFM Cantilever:
F
160 kHz
C
5 N/m
L
125 µm
HQ:NSC35/Al BS
HQ:NSC35/Al BS
AFM Probe with 3 Different Tapping Mode AFM Cantilevers
Coating: Reflective Aluminum
Tip Shape: Rotated
AFM Cantilevers: 3
1
2
3
F
205 kHz
300 kHz
150 kHz
C
8.9 N/m
16 N/m
5.4 N/m
L
110 µm
90 µm
130 µm
200AC-NA
200AC-NA
Soft Tapping Mode AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating: Reflective Aluminum
Tip Shape: Optimized Positioning
AFM Cantilever:
F
135 kHz
C
9 N/m
L
200 µm
New
OMCL-AC200TS
OMCL-AC200TS
Soft Tapping Mode AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating: Reflective Aluminum
Tip Shape: Optimized Positioning
AFM Cantilever:
F
150 kHz
C
9 N/m
L
200 µm
best bang for your buck
Tap150Al-G
Tap150Al-G
Soft Tapping Mode AFM Probe
Coating: Reflective Aluminum
Tip Shape: Rotated
AFM Cantilever:
F
150 kHz
C
5 N/m
L
125 µm
PPP-NCST
PPP-NCST
Soft Tapping Mode AFM Probe
Coating: none
Tip Shape: Standard
AFM Cantilever:
F
160 kHz
C
7.4 N/m
L
150 µm
NCST
NCST
Soft Tapping Mode AFM Probe
Coating: none
Tip Shape: Standard
AFM Cantilever:
F
160 kHz
C
7.4 N/m
L
150 µm
ATEC-FM
ATEC-FM
Force Modulation AFM Probe with REAL Tip Visibility
Coating: none
Tip Shape: Visible
AFM Cantilever:
F
85 kHz
C
2.8 N/m
L
240 µm
best of the best
PPP-FMR
PPP-FMR
Standard Force Modulation AFM Probe
Coating: Reflective Aluminum
Tip Shape: Standard
AFM Cantilever:
F
75 kHz
C
2.8 N/m
L
225 µm
ARROW-FMR
ARROW-FMR
Force Modulation AFM Probe with Tip at the Very End of the Cantilever
Coating: Reflective Aluminum
Tip Shape: Arrow
AFM Cantilever:
F
75 kHz
C
2.8 N/m
L
240 µm
the industry standard
FMR
FMR
Standard Force Modulation AFM Probe
Coating: Reflective Aluminum
Tip Shape: Standard
AFM Cantilever:
F
75 kHz
C
2.8 N/m
L
225 µm
top value
HQ:NSC18/Al BS
HQ:NSC18/Al BS
Standard Force Modulation AFM Probe
Coating: Reflective Aluminum
Tip Shape: Rotated
AFM Cantilever:
F
75 kHz
C
2.8 N/m
L
225 µm
top value
240AC-NA
240AC-NA
Force Modulation AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating: Reflective Aluminum
Tip Shape: Optimized Positioning
AFM Cantilever:
F
70 kHz
C
2 N/m
L
240 µm
New
OMCL-AC240TS
OMCL-AC240TS
Force Modulation AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating: Reflective Aluminum
Tip Shape: Optimized Positioning
AFM Cantilever:
F
70 kHz
C
2 N/m
L
240 µm
best bang for your buck
Multi75Al-G
Multi75Al-G
Standard Force Modulation AFM Probe
Coating: Reflective Aluminum
Tip Shape: Rotated
AFM Cantilever:
F
75 kHz
C
3 N/m
L
225 µm
OLTESPA
OLTESPA
Force Modulation AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating: Reflective Aluminum
Tip Shape: Optimized Positioning
AFM Cantilever:
F
70 kHz
C
2 N/m
L
240 µm
PPP-RT-FMR
PPP-RT-FMR
Standard Force Modulation AFM Probe
Coating: Reflective Aluminum
Tip Shape: Rotated
AFM Cantilever:
F
75 kHz
C
2.8 N/m
L
225 µm
PPP-QFMR
PPP-QFMR
Force Modulation AFM Probe, for UHV Conditions
Coating: Reflective Aluminum
Tip Shape: Standard
AFM Cantilever:
F
75 kHz
C
2.8 N/m
L
225 µm
4