AFM Tips at the Very End of the AFM Cantilever

AFM probes with 3-sided pyramidal macroscopic shape of the AFM tips for optimized positioning upon sample (OPUS)
Sort by:
26 results
top value
160AC-NA
160AC-NA
Standard Tapping Mode AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating: Reflective Aluminum
Tip Shape: Optimized Positioning
AFM Cantilever:
F
300 kHz
C
26 N/m
L
160 µm
OTESPA
OTESPA
Standard Tapping Mode AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating: Reflective Aluminum
Tip Shape: Optimized Positioning
AFM Cantilever:
F
300 kHz
C
26 N/m
L
160 µm
200AC-NA
200AC-NA
Soft Tapping Mode AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating: Reflective Aluminum
Tip Shape: Optimized Positioning
AFM Cantilever:
F
135 kHz
C
9 N/m
L
200 µm
top value
240AC-NA
240AC-NA
Force Modulation AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating: Reflective Aluminum
Tip Shape: Optimized Positioning
AFM Cantilever:
F
70 kHz
C
2 N/m
L
240 µm
OLTESPA
OLTESPA
Force Modulation AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating: Reflective Aluminum
Tip Shape: Optimized Positioning
AFM Cantilever:
F
70 kHz
C
2 N/m
L
240 µm
top value
160AC-SG
160AC-SG

High Resolution, Tapping Mode AFM Probe with AFM Tip at the Very End of the AFM Cantilever

Coating: Reflective Gold
Tip Shape: Supersharp,Optimized Positioning
AFM Cantilever:
F
300 kHz
C
26 N/m
L
160 µm
New
240AC-SG
240AC-SG
High Resolution, Force Modulation AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating: Reflective Gold
Tip Shape: Supersharp,Optimized Positioning
AFM Cantilever:
F
70 kHz
C
2 N/m
L
240 µm
top value
240AC-PP
240AC-PP
Electrical, Force Modulation AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating: Electrically Conductive
Tip Shape: Optimized Positioning
AFM Cantilever:
F
70 kHz
C
2 N/m
L
240 µm
OSCM-PT
OSCM-PT
Electrical, Force Modulation AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating: Electrically Conductive
Tip Shape: Optimized Positioning
AFM Cantilever:
F
70 kHz
C
2 N/m
L
240 µm
160AC-NG
160AC-NG
Gold Coated Tapping Mode AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating: Reflective Gold
Tip Shape: Optimized Positioning
AFM Cantilever:
F
300 kHz
C
26 N/m
L
160 µm
55AC-NG
55AC-NG

Gold Coated Ultra High Frequency AFM Probe with AFM Tip at the Very End of the AFM Cantilever

Coating: Reflective Gold
Tip Shape: Optimized Positioning
AFM Cantilever:
F
1200 kHz
C
85 N/m
L
65 µm
top value
55AC-NA
55AC-NA

Ultra High Frequency AFM Probe with AFM Tip at the Very End of the AFM Cantilever

Coating: Reflective Aluminum
Tip Shape: Optimized Positioning
AFM Cantilever:
F
1200 kHz
C
85 N/m
L
65 µm
55AC-NN
55AC-NN

Ultra High Frequency AFM Probe with AFM Tip at the Very End of the AFM Cantilever

Coating: none
Tip Shape: Optimized Positioning
AFM Cantilever:
F
1200 kHz
C
85 N/m
L
65 µm
top value
240AC-NG
240AC-NG
Gold Coated Force Modulation AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating: Reflective Gold
Tip Shape: Optimized Positioning
AFM Cantilever:
F
70 kHz
C
2 N/m
L
240 µm
top value
240AC-MA
240AC-MA
Hard Magnetic, Medium Momentum AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating: Magnetic
Tip Shape: Optimized Positioning
AFM Cantilever:
F
70 kHz
C
2 N/m
L
240 µm
top value
3XC-NA
3XC-NA

AFM Probe with 3 Different AFM Cantilevers for Various Applications and AFM  Tips at the Very End of the AFM Cantilevers

Coating: Reflective Aluminum
Tip Shape: Optimized Positioning
AFM Cantilevers: 3
1
2
3
F
17 kHz
150 kHz
75 kHz
C
0.3 N/m
9 N/m
2.5 N/m
L
500 µm
175 µm
240 µm
160AC-NN
160AC-NN
Standard Tapping Mode AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating: none
Tip Shape: Optimized Positioning
AFM Cantilever:
F
300 kHz
C
26 N/m
L
160 µm
240AC-NN
240AC-NN
Force Modulation AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating: none
Tip Shape: Optimized Positioning
AFM Cantilever:
F
70 kHz
C
2 N/m
L
240 µm
3XC-NN
3XC-NN
AFM Probe with 3 Different AFM Cantilevers for Various Applications and AFM  Tips at the Very End of the AFM Cantilevers
Coating: none
Tip Shape: Optimized Positioning
AFM Cantilevers: 3
1
2
3
F
17 kHz
150 kHz
75 kHz
C
0.3 N/m
9 N/m
2.5 N/m
L
500 µm
175 µm
240 µm
4XC-NN
4XC-NN
AFM Probe with 4 Different AFM Cantilevers with AFM Tips at the Very End of the AFM Cantilevers
Coating: none
Tip Shape: Optimized Positioning
AFM Cantilevers: 4
1
2
3
4
F
17 kHz
75 kHz
150 kHz
1200 kHz
C
0.3 N/m
2.5 N/m
9 N/m
100 N/m
L
500 µm
240 µm
175 µm
65 µm
2