PPP-QFMR-10 Box of 10 AFM Probes
760.00 USD
Price shown as ex-works and subjected to shipping charges, insurance, local VAT and custom duties respectively where applicable

PPP-QFMR

Force Modulation AFM Probe, for UHV Conditions

Manufacturer: NANOSENSORS

Coating: Reflective Aluminum
AFM tip shape: Standard
AFM Cantilever
F 75 kHz
C 2.8 N/m
L 225 µm
*nominal values
Applications
How to optimize AFM scan parameters gear icon

The PointProbe®Plus Q30K-Plus combines the well-known features of the proven PointProbe® Plus series such as a further reduced and more reproducible AFM tip radius as well as a more defined AFM tip shape with a high mechanical quality factor (Q-factor) under ultra high vacuum (UHV) conditions. The typical Q-factor of over 35000 under UHV conditions and the aluminum coating on the detector side provide excellent resolution and an enhanced signal to noise ratio.

The FM type is offered for force modulation microscopy. The force constant of this AFM probe spans the gap between contact and non-contact mode and is specially tailored for the force modulation mode under UHV conditions. Due to its high Q-factor and the typical features of the PPP series this AFM probe combines high operation stability with outstanding sensitivity and fast scanning ability.

The AFM probe offers unique features:

  • excellent AFM tip radius of curvature
  • highly doped silicon to dissipate static charge
  • Al coating on detector side of AFM cantilever
  • excellent mechanical Q-factor under UHV conditions for high sensitivity
  • precise alignment of the AFM cantilever position (within +/-2µm) in combination with the Alignment Chip
  • compatible with PointProbe® Plus XY-Alignment Series

This AFM probe features alignment grooves on the back side of the holder chip.

The reflex coating is an approximately 30 nm thick aluminum coating on the detector side of the AFM cantilever which enhances the reflectivity of the laser beam by a factor of about 2.5. Furthermore it prevents light from interfering within the AFM cantilever. As the coating is nearly stress-free the bending of the AFM cantilever due to stress is less than 2 degrees.
AFM Tip:

  • AFM Cantilever:
  • Beam
  • 2.8 N/m (0.5 - 9.5 N/m)*
  • 75 kHz (45 - 115 kHz)*
  • 225 µm (215 - 235 µm)*
  • 28 µm (20 - 35 µm)*
  • 3 µm ( 2 - 4 µm)*
  • * guaranteed range