NanoAndMore GmbH does not ship to your country
Silicon AFM Tips
AFM probes with silicon AFM tips
Sort by:
281 results
top value
HQ:DMD-XSC11
AFM Probe with 4 Different Diamond Coated, Conductive Cantilevers for Various Applications
Coating:
Conductive Diamond
Tip Shape: Rotated
Tip Shape: Rotated
AFM Cantilevers: 4
1
2
3
4
F
18 kHz
110 kHz
210 kHz
450 kHz
C
0.5 N/m
6.5 N/m
18 N/m
95 N/m
L
500 µm
210 µm
150 µm
100 µm
HQ:NSC36/Pt
AFM Probe with 3 Different Electrical, Force Modulation Mode AFM Cantilevers
Coating:
Electrically Conductive
Tip Shape: Rotated
Tip Shape: Rotated
AFM Cantilevers: 3
1
2
3
F
90 kHz
130 kHz
65 kHz
C
1 N/m
2 N/m
0.6 N/m
L
110 µm
90 µm
130 µm
HQ:DPER-XSC11
AFM Probe with 4 Different Electrical AFM Cantilevers
Coating:
Electrically Conductive
Tip Shape: Rotated
Tip Shape: Rotated
AFM Cantilevers: 4
1
2
3
4
F
15 kHz
80 kHz
155 kHz
350 kHz
C
0.2 N/m
2.7 N/m
7 N/m
42 N/m
L
500 µm
210 µm
150 µm
100 µm
HQ:DPE-XSC11
AFM Probe with 4 Different Electrical Cantilevers
Coating:
Electrically Conductive
Tip Shape: Rotated
Tip Shape: Rotated
AFM Cantilevers: 4
1
2
3
4
F
15 kHz
80 kHz
155 kHz
350 kHz
C
0.2 N/m
2.7 N/m
7 N/m
42 N/m
L
500 µm
210 µm
150 µm
100 µm
HQ:NSC15/Pt
Electrical, Tapping Mode AFM Probe
Coating:
Electrically Conductive
Tip Shape: Rotated
Tip Shape: Rotated
AFM Cantilever:
F
325 kHz
C
40 N/m
L
125 µm
ElectriAll-In-One
Electrical AFM Probe with 4 Different AFM Cantilevers
Coating:
Electrically Conductive
Tip Shape: Rotated
Tip Shape: Rotated
AFM Cantilevers: 4
1
2
3
4
F
15 kHz
80 kHz
150 kHz
350 kHz
C
0.2 N/m
2.7 N/m
7.4 N/m
40 N/m
L
500 µm
210 µm
150 µm
100 µm
NCLPt
Electrical, Tapping Mode AFM Probe with a Long Cantilever
Coating:
Electrically Conductive
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
190 kHz
C
48 N/m
L
225 µm
HQ:NSC16/Pt
Electrical, Tapping Mode AFM Probe with Long AFM Cantilever
Coating:
Electrically Conductive
Tip Shape: Rotated
Tip Shape: Rotated
AFM Cantilever:
F
190 kHz
C
45 N/m
L
225 µm
HQ:NSC14/Pt
Electrical, Soft Tapping Mode AFM Probe
Coating:
Electrically Conductive
Tip Shape: Rotated
Tip Shape: Rotated
AFM Cantilever:
F
160 kHz
C
5 N/m
L
125 µm
HQ:XSC11/Pt
AFM Probe with 4 Different Electrical Cantilevers
Coating:
Electrically Conductive
Tip Shape: Rotated
Tip Shape: Rotated
AFM Cantilevers: 4
1
2
3
4
F
15 kHz
80 kHz
155 kHz
350 kHz
C
0.2 N/m
2.7 N/m
7 N/m
42 N/m
L
500 µm
210 µm
150 µm
100 µm
ElectriTap300-G
Electrical, Tapping Mode AFM Probe
Coating:
Electrically Conductive
Tip Shape: Rotated
Tip Shape: Rotated
AFM Cantilever:
F
300 kHz
C
40 N/m
L
125 µm
ElectriTap190-G
Electrical, Tapping Mode AFM Probe with Long AFM Cantilever
Coating:
Electrically Conductive
Tip Shape: Rotated
Tip Shape: Rotated
AFM Cantilever:
F
190 kHz
C
48 N/m
L
225 µm
ElectriTap150-G
Electrical, Soft Tapping Mode AFM Probe
Coating:
Electrically Conductive
Tip Shape: Rotated
Tip Shape: Rotated
AFM Cantilever:
F
150 kHz
C
5 N/m
L
125 µm
PPP-CONTPt
Electrical, Contact Mode AFM Probe
Coating:
Electrically Conductive
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
13 kHz
C
0.2 N/m
L
450 µm
PPP-CONTSCPt
Electrical, Contact Mode AFM Probe with Short AFM Cantilever
Coating:
Electrically Conductive
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
25 kHz
C
0.2 N/m
L
225 µm
ATEC-CONTPt
Electrical, Contact Mode AFM Probe with REAL Tip Visibility
Coating:
Electrically Conductive
Tip Shape: Visible
Tip Shape: Visible
AFM Cantilever:
F
15 kHz
C
0.2 N/m
L
450 µm
ARROW-CONTPt
Electrical, Contact Mode AFM Probe with Tip at the Very End of the Cantilever
Coating:
Electrically Conductive
Tip Shape: Arrow
Tip Shape: Arrow
AFM Cantilever:
F
14 kHz
C
0.2 N/m
L
450 µm
CONTPt
Electrical, Contact Mode AFM Probe
Coating:
Electrically Conductive
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
13 kHz
C
0.2 N/m
L
450 µm
ElectriCont-G
Electrical, Contact Mode AFM Probe
Coating:
Electrically Conductive
Tip Shape: Rotated
Tip Shape: Rotated
AFM Cantilever:
F
13 kHz
C
0.2 N/m
L
450 µm
HQ:CSC37/Pt
AFM Probe with 3 Different Electrical, Contact Mode AFM Cantilevers
Coating:
Electrically Conductive
Tip Shape: Rotated
Tip Shape: Rotated
AFM Cantilevers: 3
1
2
3
F
40 kHz
20 kHz
30 kHz
C
0.8 N/m
0.3 N/m
0.4 N/m
L
250 µm
350 µm
300 µm