1 Single AFM Cantilever per AFM Probe

AFM probes with one single AFM cantilever
Sort by:
340 results
the industry standard
NW-AR5T-NCHR
NW-AR5T-NCHR
High-Aspect-Ratio, Tilt Compensated Tapping Mode AFM Probe
Coating: Reflective Aluminum
Tip Shape: High-Aspect-Ratio
AFM Cantilever:
F
330 kHz
C
42 N/m
L
125 µm
TESPA-HAR
TESPA-HAR

High-Aspect-Ratio, Tapping Mode AFM Probe

Coating: Reflective Aluminum
Tip Shape: High-Aspect-Ratio
AFM Cantilever:
F
320 kHz
C
42 N/m
L
125 µm
USC-F2-k3
USC-F2-k3
Ultra-Short Cantilever (USC) mainly dedicated to dynamic High-Speed AFM applications in air
Coating: Reflective Gold
Tip Shape: Cone Shaped,EBD
AFM Cantilever:
F
2000 kHz
C
3 N/m
L
10 µm
USC-F1.2-k7.3
USC-F1.2-k7.3
Ultra-Short Cantilever (USC) mainly dedicated to dynamic High-Speed AFM applications in air
Coating: Reflective Gold
Tip Shape: Cone Shaped,EBD
AFM Cantilever:
F
1200 kHz
C
7.3 N/m
L
20 µm
the industry standard
ARROW-UHF
ARROW-UHF
Ultra High Frequency AFM Probe with Tip at the Very End of the Cantilever
Coating: Reflective Aluminum
Tip Shape: Arrow
AFM Cantilever:
F
2000 kHz
C
x
L
35 µm
PPP-CONT
PPP-CONT
Standard Contact Mode AFM Probe
Coating: none
Tip Shape: Standard
AFM Cantilever:
F
13 kHz
C
0.2 N/m
L
450 µm
qp-CONT
qp-CONT
uniqprobe™ - uniform quality SPM probe for contact mode
Coating: Reflective Gold
Tip Shape: Circular symmetric
AFM Cantilever:
F
30 kHz
C
0.1 N/m
L
125 µm
best of the best
qp-SCONT
qp-SCONT
uniqprobe™ - uniform quality SPM probe for soft contact mode
Coating: Reflective Gold
Tip Shape: Circular symmetric
AFM Cantilever:
F
11 kHz
C
0.01 N/m
L
125 µm
CONT
CONT
Standard Contact Mode AFM Probe
Coating: none
Tip Shape: Standard
AFM Cantilever:
F
13 kHz
C
0.2 N/m
L
450 µm
ESPA
ESPA

Standard Contact Mode AFM Probe

Coating: Reflective Aluminum
Tip Shape: Standard
AFM Cantilever:
F
13 kHz
C
0.2 N/m
L
450 µm
CONTSCR
CONTSCR
Contact Mode AFM Probe with Short Cantilever
Coating: Reflective Aluminum
Tip Shape: Standard
AFM Cantilever:
F
25 kHz
C
0.2 N/m
L
225 µm
Contact-G
Contact-G
Standard Contact Mode AFM Probe
Coating: none
Tip Shape: Rotated
AFM Cantilever:
F
13 kHz
C
0.2 N/m
L
450 µm
HQ:CSC17/No Al
HQ:CSC17/No Al
Standard Contact Mode AFM Probe
Coating: none
Tip Shape: Rotated
AFM Cantilever:
F
13 kHz
C
0.18 N/m
L
450 µm
sale
ARROW-CONT
ARROW-CONT
Contact Mode AFM Probe with Tip at the Very End of the Cantilever
Coating: none
Tip Shape: Arrow
AFM Cantilever:
F
14 kHz
C
0.2 N/m
L
450 µm
CONTSC
CONTSC
Contact Mode AFM Probe with Short Cantilever
Coating: none
Tip Shape: Standard
AFM Cantilever:
F
25 kHz
C
0.2 N/m
L
225 µm
PPP-CONTAuD
PPP-CONTAuD
Gold Coated Contact Mode AFM Probe
Coating: Reflective Gold
Tip Shape: Standard
AFM Cantilever:
F
13 kHz
C
0.2 N/m
L
450 µm
PPP-CONTSCAuD
PPP-CONTSCAuD
Gold Coated Contact Mode AFM Probe with Short AFM Cantilever
Coating: Reflective Gold
Tip Shape: Standard
AFM Cantilever:
F
25 kHz
C
0.2 N/m
L
225 µm
ContGD-G
ContGD-G
Gold Coated Contact Mode AFM Probe
Coating: Reflective Gold
Tip Shape: Rotated
AFM Cantilever:
F
13 kHz
C
0.2 N/m
L
450 µm
HQ:CSC17/Cr-Au BS
HQ:CSC17/Cr-Au BS
Gold Coated Contact Mode AFM Probe
Coating: Reflective Gold
Tip Shape: Rotated
AFM Cantilever:
F
13 kHz
C
0.18 N/m
L
450 µm
PPP-BSI
PPP-BSI
Soft Contact AFM Probe for Biological Applications
Coating: none
Tip Shape: Standard
AFM Cantilever:
F
28 kHz
C
0.1 N/m
L
225 µm
17