NanoAndMore SEA does not ship to your country
Rectangular Cross Section AFM Cantilevers
AFM probes with rectangular cross section AFM cantilevers
Sort by:
49 results
55AC-NN
Ultra High Frequency AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating:
none
Tip Shape: Optimized Positioning
Tip Shape: Optimized Positioning
AFM Cantilever:
F
1200 kHz
C
85 N/m
L
65 µm
PNP-TRS
Silicon Nitride AFM Probe Single Cantilever Compatible with ScanAsyst®** Mode
Coating:
Reflective Gold
Tip Shape: Pyramid
Tip Shape: Pyramid
AFM Cantilever:
F
67 kHz
C
0.32 N/m
L
100 µm
top value
240AC-NG
Gold Coated Force Modulation AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating:
Reflective Gold
Tip Shape: Optimized Positioning
Tip Shape: Optimized Positioning
AFM Cantilever:
F
70 kHz
C
2 N/m
L
240 µm
top value
240AC-MA
Hard Magnetic, Medium Momentum AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating:
Magnetic
Tip Shape: Optimized Positioning
Tip Shape: Optimized Positioning
AFM Cantilever:
F
70 kHz
C
2 N/m
L
240 µm
top value
3XC-NA
AFM Probe with 3 Different AFM Cantilevers for Various Applications and AFM Tips at the Very End of the AFM Cantilevers
Coating:
Reflective Aluminum
Tip Shape: Optimized Positioning
Tip Shape: Optimized Positioning
AFM Cantilevers: 3
1
2
3
F
17 kHz
150 kHz
75 kHz
C
0.3 N/m
9 N/m
2.5 N/m
L
500 µm
175 µm
240 µm
160AC-NN
Standard Tapping Mode AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating:
none
Tip Shape: Optimized Positioning
Tip Shape: Optimized Positioning
AFM Cantilever:
F
300 kHz
C
26 N/m
L
160 µm
240AC-NN
Force Modulation AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating:
none
Tip Shape: Optimized Positioning
Tip Shape: Optimized Positioning
AFM Cantilever:
F
70 kHz
C
2 N/m
L
240 µm
3XC-NN
AFM Probe with 3 Different AFM Cantilevers for Various Applications and AFM Tips at the Very End of the AFM Cantilevers
Coating:
none
Tip Shape: Optimized Positioning
Tip Shape: Optimized Positioning
AFM Cantilevers: 3
1
2
3
F
17 kHz
150 kHz
75 kHz
C
0.3 N/m
9 N/m
2.5 N/m
L
500 µm
175 µm
240 µm
4XC-NN
AFM Probe with 4 Different AFM Cantilevers with AFM Tips at the Very End of the AFM Cantilevers
Coating:
none
Tip Shape: Optimized Positioning
Tip Shape: Optimized Positioning
AFM Cantilevers: 4
1
2
3
4
F
17 kHz
75 kHz
150 kHz
1200 kHz
C
0.3 N/m
2.5 N/m
9 N/m
100 N/m
L
500 µm
240 µm
175 µm
65 µm
best bang for your buck
SiNi
Silicon Nitride AFM Probe with 2 Different AFM Cantilevers on Each Side of the Chip
Coating:
Reflective Gold
Tip Shape: Pyramid
Tip Shape: Pyramid
AFM Cantilevers: 4
1
2
F
30 kHz
10 kHz
C
0.27 N/m
0.06 N/m
L
100 µm
200 µm
top value
160AC-FG
High Aspect Ratio, Tapping Mode AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating:
Reflective Gold
Tip Shape: High-Aspect-Ratio
Tip Shape: High-Aspect-Ratio
AFM Cantilever:
F
300 kHz
C
26 N/m
L
160 µm
New
240AC-FG
High Aspect Ratio, Force Modulation AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating:
Reflective Gold
Tip Shape: High-Aspect-Ratio
Tip Shape: High-Aspect-Ratio
AFM Cantilever:
F
70 kHz
C
2 N/m
L
240 µm
PNP-TR-Au
Gold Coated Silicon Nitride AFM Probe
Coating:
Gold Overall
Tip Shape: Pyramid
Tip Shape: Pyramid
AFM Cantilevers: 2
1
2
F
67 kHz
17 kHz
C
0.32 N/m
0.08 N/m
L
100 µm
200 µm
3XC-GG
AFM Probe with 3 Different Gold Coated AFM Cantilevers for Various Applications and AFM Tips at the Very End of the AFM Cantilevers
Coating:
Gold Overall
Tip Shape: Optimized Positioning
Tip Shape: Optimized Positioning
AFM Cantilevers: 3
1
2
3
F
17 kHz
150 kHz
75 kHz
C
0.3 N/m
9 N/m
2.5 N/m
L
500 µm
175 µm
240 µm
4XC-GG
AFM Probe with 4 Different Gold Coated AFM Cantilevers with AFM Tips at the Very End of the AFM Cantilevers
Coating:
Gold Overall
Tip Shape: Optimized Positioning
Tip Shape: Optimized Positioning
AFM Cantilevers: 4
1
2
3
4
F
17 kHz
75 kHz
150 kHz
1200 kHz
C
0.3 N/m
2.5 N/m
9 N/m
100 N/m
L
500 µm
240 µm
175 µm
65 µm
240AC-GG
Gold Coated Force Modulation AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating:
Gold Overall
Tip Shape: Optimized Positioning
Tip Shape: Optimized Positioning
AFM Cantilever:
F
70 kHz
C
2 N/m
L
240 µm
XNC12/Cr-Au
AFM Probe with 2 Different Gold Coated Silicon Nitride AFM Cantilevers
Coating:
Gold Overall
Tip Shape: Pyramid
Tip Shape: Pyramid
AFM Cantilevers: 2
1
2
F
17 kHz
67 kHz
C
0.08 N/m
0.32 N/m
L
200 µm
100 µm
Mix and Match Box
Mixed box: up to 400 MikroMasch AFM probes
Coating:
various
Tip Shape: various
Tip Shape: various
160AC-GG
Gold Coated Tapping Mode AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating:
Gold Overall
Tip Shape: Optimized Positioning
Tip Shape: Optimized Positioning
AFM Cantilever:
F
300 kHz
C
26 N/m
L
160 µm
PNP-TR-TL
Tipless Silicon Nitride AFM Cantilever
Coating:
Reflective Gold
Tip Shape: Tipless
Tip Shape: Tipless
AFM Cantilevers: 2
1
2
F
67 kHz
17 kHz
C
0.32 N/m
0.08 N/m
L
100 µm
200 µm