Rectangular Cross Section AFM Cantilevers

AFM probes with rectangular cross section AFM cantilevers
Sort by:
49 results
top value
160AC-NA
160AC-NA
Standard Tapping Mode AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating: Reflective Aluminum
Tip Shape: Optimized Positioning
AFM Cantilever:
F
300 kHz
C
26 N/m
L
160 µm
New
OMCL-AC160TS
OMCL-AC160TS
Standard Tapping Mode AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating: Reflective Aluminum
Tip Shape: Optimized Positioning
AFM Cantilever:
F
300 kHz
C
26 N/m
L
160 µm
OTESPA
OTESPA
Standard Tapping Mode AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating: Reflective Aluminum
Tip Shape: Optimized Positioning
AFM Cantilever:
F
300 kHz
C
26 N/m
L
160 µm
200AC-NA
200AC-NA
Soft Tapping Mode AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating: Reflective Aluminum
Tip Shape: Optimized Positioning
AFM Cantilever:
F
135 kHz
C
9 N/m
L
200 µm
New
OMCL-AC200TS
OMCL-AC200TS
Soft Tapping Mode AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating: Reflective Aluminum
Tip Shape: Optimized Positioning
AFM Cantilever:
F
150 kHz
C
9 N/m
L
200 µm
top value
240AC-NA
240AC-NA
Force Modulation AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating: Reflective Aluminum
Tip Shape: Optimized Positioning
AFM Cantilever:
F
70 kHz
C
2 N/m
L
240 µm
New
OMCL-AC240TS
OMCL-AC240TS
Force Modulation AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating: Reflective Aluminum
Tip Shape: Optimized Positioning
AFM Cantilever:
F
70 kHz
C
2 N/m
L
240 µm
OLTESPA
OLTESPA
Force Modulation AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating: Reflective Aluminum
Tip Shape: Optimized Positioning
AFM Cantilever:
F
70 kHz
C
2 N/m
L
240 µm
top value
160AC-SG
160AC-SG

High Resolution, Tapping Mode AFM Probe with AFM Tip at the Very End of the AFM Cantilever

Coating: Reflective Gold
Tip Shape: Supersharp,Optimized Positioning
AFM Cantilever:
F
300 kHz
C
26 N/m
L
160 µm
240AC-SG
240AC-SG
High Resolution, Force Modulation AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating: Reflective Gold
Tip Shape: Supersharp,Optimized Positioning
AFM Cantilever:
F
70 kHz
C
2 N/m
L
240 µm
top value
240AC-PP
240AC-PP
Electrical, Force Modulation AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating: Electrically Conductive
Tip Shape: Optimized Positioning
AFM Cantilever:
F
70 kHz
C
2 N/m
L
240 µm
New
OMCL-AC240TM
OMCL-AC240TM
Electrical, Force Modulation AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating: Electrically Conductive
Tip Shape: Optimized Positioning
AFM Cantilever:
F
70 kHz
C
2 N/m
L
240 µm
OSCM-PT
OSCM-PT
Electrical, Force Modulation AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating: Electrically Conductive
Tip Shape: Optimized Positioning
AFM Cantilever:
F
70 kHz
C
2 N/m
L
240 µm
160AC-NG
160AC-NG
Gold Coated Tapping Mode AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating: Reflective Gold
Tip Shape: Optimized Positioning
AFM Cantilever:
F
300 kHz
C
26 N/m
L
160 µm
The Standard SiNi probe
PNP-TR
PNP-TR
Silicon Nitride AFM Probe
Coating: Reflective Gold
Tip Shape: Pyramid
AFM Cantilevers: 2
1
2
F
67 kHz
17 kHz
C
0.32 N/m
0.08 N/m
L
100 µm
200 µm
PNP-DB
PNP-DB
Silicon Nitride AFM Probe
Coating: Reflective Gold
Tip Shape: Pyramid
AFM Cantilevers: 2
1
2
F
67 kHz
17 kHz
C
0.48 N/m
0.06 N/m
L
100 µm
200 µm
top value
XNC12/Cr-Au BS
XNC12/Cr-Au BS
AFM Probe with 2 Different Gold Coated Silicon Nitride AFM Cantilevers
Coating: Reflective Gold
Tip Shape: Pyramid
AFM Cantilevers: 2
1
2
F
17 kHz
67 kHz
C
0.08 N/m
0.32 N/m
L
200 µm
100 µm
55AC-NG
55AC-NG

Gold Coated Ultra High Frequency AFM Probe with AFM Tip at the Very End of the AFM Cantilever

Coating: Reflective Gold
Tip Shape: Optimized Positioning
AFM Cantilever:
F
1200 kHz
C
85 N/m
L
65 µm
top value
55AC-NA
55AC-NA

Ultra High Frequency AFM Probe with AFM Tip at the Very End of the AFM Cantilever

Coating: Reflective Aluminum
Tip Shape: Optimized Positioning
AFM Cantilever:
F
1200 kHz
C
85 N/m
L
65 µm
New
OMCL-AC55TS
OMCL-AC55TS
Ultra High Frequency AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating: Reflective Gold
Tip Shape: Optimized Positioning
AFM Cantilever:
F
1600 kHz
C
85 N/m
L
55 µm
3