NanoAndMore SEA does not ship to your country
AFM Support Chips with Alignment Grooves
AFM probes with support chips wtih alignment grooves
Sort by:
289 results


SSS-MFMR
SuperSharp, Hard Magnetic, Low Momentum MFM AFM Probe
Coating:
Magnetic
Tip Shape: Supersharp
Tip Shape: Supersharp
AFM Cantilever:
F
75 kHz
C
2.8 N/m
L
225 µm
the industry standard


MFMR
Hard Magnetic, Medium Momentum MFM AFM Probe
Coating:
Magnetic
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
75 kHz
C
2.8 N/m
L
225 µm


S-MFMR
Soft Magnetic, Medium Momentum MFM AFM Probe
Coating:
Magnetic
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
75 kHz
C
2.8 N/m
L
225 µm
top value


HQ:NSC18/Co-Cr/Al BS
Hard Magnetic, Medium Momentum MFM AFM Probe
Coating:
Magnetic
Tip Shape: Rotated
Tip Shape: Rotated
AFM Cantilever:
F
75 kHz
C
2.8 N/m
L
225 µm
top value


240AC-MA
Hard Magnetic, Medium Momentum AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating:
Magnetic
Tip Shape: Optimized Positioning
Tip Shape: Optimized Positioning
AFM Cantilever:
F
70 kHz
C
2 N/m
L
240 µm
best bang for your buck


MagneticMulti75-G
Hard Magnetic, Medium Momentum AFM Probe
Coating:
Magnetic
Tip Shape: Rotated
Tip Shape: Rotated
AFM Cantilever:
F
75 kHz
C
3 N/m
L
225 µm


PPP-NCH
Standard Tapping Mode AFM Probe
Coating:
none
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
330 kHz
C
42 N/m
L
125 µm


PPP-NCL
Tapping Mode AFM Probe, Long AFM Cantilever
Coating:
none
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
190 kHz
C
48 N/m
L
225 µm


NCH
Standard Tapping Mode AFM Probe
Coating:
none
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
320 kHz
C
42 N/m
L
125 µm


TESP
Standard Tapping Mode AFM Probe
Coating:
none
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
320 kHz
C
42 N/m
L
125 µm


LTESP
Tapping Mode AFM Probe, Long Cantilever
Coating:
none
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
190 kHz
C
48 N/m
L
225 µm


NCL
Tapping Mode AFM Probe, Long Cantilever
Coating:
none
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
190 kHz
C
48 N/m
L
225 µm


HQ:NSC15/No Al
Standard Tapping Mode AFM Probe
Coating:
none
Tip Shape: Rotated
Tip Shape: Rotated
AFM Cantilever:
F
325 kHz
C
40 N/m
L
125 µm


HQ:NSC16/No Al
Tapping Mode AFM Probe with Long AFM Cantilever
Coating:
none
Tip Shape: Rotated
Tip Shape: Rotated
AFM Cantilever:
F
190 kHz
C
45 N/m
L
225 µm


160AC-NN
Standard Tapping Mode AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating:
none
Tip Shape: Optimized Positioning
Tip Shape: Optimized Positioning
AFM Cantilever:
F
300 kHz
C
26 N/m
L
160 µm


Tap300-G
Standard Tapping Mode AFM Probe
Coating:
none
Tip Shape: Rotated
Tip Shape: Rotated
AFM Cantilever:
F
300 kHz
C
40 N/m
L
125 µm


Tap190-G
Tapping Mode AFM Probe with Long AFM Cantilever
Coating:
none
Tip Shape: Rotated
Tip Shape: Rotated
AFM Cantilever:
F
190 kHz
C
48 N/m
L
225 µm
New


biotool cell XXL
Extralong 15 um EBD carbon whisker with 25 nm radius on soft AFM cantilever
Coating:
Reflective Gold
Tip Shape: EBD,Cone Shaped
Tip Shape: EBD,Cone Shaped
AFM Cantilever:
F
50 kHz
C
0.1 N/m
L
60 µm


FESP
Standard Force Modulation AFM Probe
Coating:
none
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
75 kHz
C
2.8 N/m
L
225 µm


240AC-NN
Force Modulation AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating:
none
Tip Shape: Optimized Positioning
Tip Shape: Optimized Positioning
AFM Cantilever:
F
70 kHz
C
2 N/m
L
240 µm