NanoAndMore SEA does not ship to your country
3-sided Sharpened Pyramidal AFM Tips
AFM probes with 3-sided sharpened pyramidal active part of the AFM tips
Sort by:
248 results
ATEC-EFM
Electrical, Force Modulation AFM Probe with REAL Tip Visibility
Coating:
Electrically Conductive
Tip Shape: Visible
Tip Shape: Visible
AFM Cantilever:
F
85 kHz
C
2.8 N/m
L
240 µm
the industry standard
NW-CDT-FMR
Diamond Coated, Conductive Force Modulation AFM Probe
Coating:
Diamond,Conductive Diamond
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
105 kHz
C
6.2 N/m
L
225 µm
ARROW-EFM
Electrical, Force Modulation AFM Probe with Tip at the Very End of the Cantilever
Coating:
Electrically Conductive
Tip Shape: Arrow
Tip Shape: Arrow
AFM Cantilever:
F
75 kHz
C
2.8 N/m
L
240 µm
the industry standard
EFM
Electrical, Force Modulation AFM Probe
Coating:
Electrically Conductive
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
75 kHz
C
2.8 N/m
L
225 µm
top value
HQ:NSC18/Pt
Electrical, Force Modulation AFM Probe
Coating:
Electrically Conductive
Tip Shape: Rotated
Tip Shape: Rotated
AFM Cantilever:
F
75 kHz
C
2.8 N/m
L
225 µm
top value
240AC-PP
Electrical, Force Modulation AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating:
Electrically Conductive
Tip Shape: Optimized Positioning
Tip Shape: Optimized Positioning
AFM Cantilever:
F
70 kHz
C
2 N/m
L
240 µm
New
OMCL-AC240TM
Electrical, Force Modulation AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating:
Electrically Conductive
Tip Shape: Optimized Positioning
Tip Shape: Optimized Positioning
AFM Cantilever:
F
70 kHz
C
2 N/m
L
240 µm
best bang for your buck
ElectriMulti75-G
Electrical, Force Modulation AFM Probe
Coating:
Electrically Conductive
Tip Shape: Rotated
Tip Shape: Rotated
AFM Cantilever:
F
75 kHz
C
3 N/m
L
225 µm
CDT-CONTR
Diamond Coated, Conductive Contact Mode AFM Probe
Coating:
Diamond,Conductive Diamond
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
20 kHz
C
0.5 N/m
L
450 µm
DDESP
Diamond Coated, Conductive Tapping Mode AFM Probe
Coating:
Diamond
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
400 kHz
C
80 N/m
L
125 µm
DDESP-FM
Diamond Coated, Conductive Force Modulation AFM Probe
Coating:
Diamond
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
105 kHz
C
6.2 N/m
L
225 µm
OSCM-PT
Electrical, Force Modulation AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating:
Electrically Conductive
Tip Shape: Optimized Positioning
Tip Shape: Optimized Positioning
AFM Cantilever:
F
70 kHz
C
2 N/m
L
240 µm
HQ:NSC35/Pt
AFM Probe with 3 Different Electrical, Tapping Mode AFM Cantilevers
Coating:
Electrically Conductive
Tip Shape: Rotated
Tip Shape: Rotated
AFM Cantilevers: 3
1
2
3
F
205 kHz
300 kHz
150 kHz
C
8.9 N/m
16 N/m
5.4 N/m
L
110 µm
90 µm
130 µm
best bang for your buck
All-In-One-DD
Diamond Coated, Conductive AFM Probe with 4 Different AFM Cantilevers
Coating:
Conductive Diamond
Tip Shape: Rotated
Tip Shape: Rotated
AFM Cantilevers: 4
1
2
3
4
F
19 kHz
110 kHz
200 kHz
450 kHz
C
0.5 N/m
6.5 N/m
18 N/m
100 N/m
L
500 µm
210 µm
150 µm
100 µm
PPP-NCSTAuD
Gold Coated Soft Tapping Mode AFM Probe
Coating:
Reflective Gold
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
160 kHz
C
7.4 N/m
L
150 µm
PPP-FMAuD
Gold Coated Force Modulation AFM Probe
Coating:
Reflective Gold
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
75 kHz
C
2.8 N/m
L
225 µm
ARROW-UHFAuD
Ultra High Frequency AFM Probe with Tip at the Very End of the Cantilever
Coating:
Reflective Gold
Tip Shape: Arrow
Tip Shape: Arrow
AFM Cantilever:
F
2000 kHz
C
x
L
35 µm
HQ:NSC14/Cr-Au BS
Gold Coated Soft Tapping Mode AFM Probe
Coating:
Reflective Gold
Tip Shape: Rotated
Tip Shape: Rotated
AFM Cantilever:
F
160 kHz
C
5 N/m
L
125 µm
top value
HQ:NSC18/Cr-Au BS
Gold Coated Force Modulation AFM Probe
Coating:
Reflective Gold
Tip Shape: Rotated
Tip Shape: Rotated
AFM Cantilever:
F
75 kHz
C
2.8 N/m
L
225 µm
160AC-NG
Gold Coated Tapping Mode AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating:
Reflective Gold
Tip Shape: Optimized Positioning
Tip Shape: Optimized Positioning
AFM Cantilever:
F
300 kHz
C
26 N/m
L
160 µm