1 Single AFM Cantilever per AFM Probe

AFM probes with one single AFM cantilever
Sort by:
340 results
HQ:NSC19/No Al
HQ:NSC19/No Al
Standard Force Modulation AFM Probe
Coating: none
Tip Shape: Rotated
AFM Cantilever:
F
65 kHz
C
0.5 N/m
L
125 µm
Multi75-G
Multi75-G
Standard Force Modulation AFM Probe
Coating: none
Tip Shape: Rotated
AFM Cantilever:
F
75 kHz
C
3 N/m
L
225 µm
SSS-NCL
SSS-NCL
SuperSharp, Tapping Mode AFM Probe with Long AFM Cantilever
Coating: none
Tip Shape: Supersharp
AFM Cantilever:
F
190 kHz
C
48 N/m
L
225 µm
NW-SSS-NCL
NW-SSS-NCL
SuperSharp, Tapping Mode AFM Probe with Long Cantilever
Coating: none
Tip Shape: Supersharp
AFM Cantilever:
F
190 kHz
C
48 N/m
L
225 µm
SSS-FM
SSS-FM
SuperSharp, Force Modulation AFM Probe
Coating: none
Tip Shape: Supersharp
AFM Cantilever:
F
75 kHz
C
2.8 N/m
L
225 µm
HiRes-C18/Cr-Au
HiRes-C18/Cr-Au
High Resolution, Soft Tapping Mode AFM Probe
Coating: Reflective Gold
Tip Shape: Supersharp
AFM Cantilever:
F
75 kHz
C
2.8 N/m
L
225 µm
HiRes-C14/Cr-Au
HiRes-C14/Cr-Au
High Resolution, Soft Tapping Mode AFM Probe
Coating: Reflective Gold
Tip Shape: Supersharp
AFM Cantilever:
F
160 kHz
C
5 N/m
L
125 µm
SHR300
SHR300
High Resolution Tapping Mode AFM Probe
Coating: Reflective Gold
Tip Shape: Supersharp
AFM Cantilever:
F
300 kHz
C
40 N/m
L
125 µm
SuperSharp Enhanced
SuperSharp Enhanced
Ultrasharp EBD AFM whisker for high-resolution, non-contact AFM
Coating: Reflective Aluminum
Tip Shape: Cone Shaped,Supersharp,EBD
AFM Cantilever:
F
320 kHz
C
40 N/m
L
120 µm
SuperSharpStandard-NCH
SuperSharpStandard-NCH
SuperSharp diamond-like EBD whisker for non-contact AFM
Coating: Reflective Aluminum
Tip Shape: Cone Shaped,Supersharp,EBD
AFM Cantilever:
F
330 kHz
C
40 N/m
L
125 µm
SuperSharp Enhanced-soft
SuperSharp Enhanced-soft
Ultrasharp EBD AFM whisker for high-resolution, soft tapping AFM
Coating: Reflective Aluminum
Tip Shape: Cone Shaped,Supersharp,EBD
AFM Cantilever:
F
75 kHz
C
2.8 N/m
L
225 µm
HQ:NSC16/Hard/Al BS
HQ:NSC16/Hard/Al BS
Long Scanning, DLC Hardened Tapping Mode AFM Probe with Long AFM Cantilever
Coating: Hard Diamond-Like-Carbon
Tip Shape: Rotated
AFM Cantilever:
F
190 kHz
C
45 N/m
L
225 µm
HQ:NSC18/Hard/Al BS
HQ:NSC18/Hard/Al BS
Long Scanning, DLC Hardened Force Modulation AFM Probe
Coating: Hard Diamond-Like-Carbon
Tip Shape: Rotated
AFM Cantilever:
F
75 kHz
C
2.8 N/m
L
225 µm
Tap150DLC
Tap150DLC
Diamond-Like-Carbon Coated Soft Tapping Mode AFM Probe
Coating: Hard Diamond-Like-Carbon
Tip Shape: Rotated
AFM Cantilever:
F
150 kHz
C
5 N/m
L
125 µm
Tap190DLC
Tap190DLC
Diamond-Like-Carbon Coated Tapping Mode AFM Probe with Long AFM Cantilever
Coating: Hard Diamond-Like-Carbon
Tip Shape: Rotated
AFM Cantilever:
F
190 kHz
C
48 N/m
L
225 µm
DT-CONTR
DT-CONTR
Diamond Coated Contact Mode AFM Probe
Coating: Diamond
Tip Shape: Standard
AFM Cantilever:
F
20 kHz
C
0.5 N/m
L
450 µm
HQ:CSC17/Hard/Al BS
HQ:CSC17/Hard/Al BS
Long Scanning, DLC Hardened Contact Mode AFM Probe
Coating: Hard Diamond-Like-Carbon
Tip Shape: Rotated
AFM Cantilever:
F
13 kHz
C
0.18 N/m
L
450 µm
ContDLC
ContDLC
Diamond-Like-Carbon Coated Contact Mode AFM Probe
Coating: Hard Diamond-Like-Carbon
Tip Shape: Rotated
AFM Cantilever:
F
13 kHz
C
0.2 N/m
L
450 µm
best of the best
AR10T-NCHR
AR10T-NCHR
High-Aspect-Ratio, Tilt Compensated Tapping Mode AFM Probe
Coating: Reflective Aluminum
Tip Shape: High-Aspect-Ratio
AFM Cantilever:
F
330 kHz
C
42 N/m
L
125 µm
AR5T-NCHR
AR5T-NCHR
High-Aspect-Ratio, Tilt Compensated Tapping Mode AFM Probe
Coating: Reflective Aluminum
Tip Shape: High-Aspect-Ratio
AFM Cantilever:
F
330 kHz
C
42 N/m
L
125 µm
17