NanoAndMore SEA does not ship to your country
1 Single AFM Cantilever per AFM Probe
AFM probes with one single AFM cantilever
Sort by:
335 results


LTESP
Tapping Mode AFM Probe, Long Cantilever
Coating:
none
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
190 kHz
C
48 N/m
L
225 µm


NCL
Tapping Mode AFM Probe, Long Cantilever
Coating:
none
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
190 kHz
C
48 N/m
L
225 µm


HQ:NSC15/No Al
Standard Tapping Mode AFM Probe
Coating:
none
Tip Shape: Rotated
Tip Shape: Rotated
AFM Cantilever:
F
325 kHz
C
40 N/m
L
125 µm


HQ:NSC16/No Al
Tapping Mode AFM Probe with Long AFM Cantilever
Coating:
none
Tip Shape: Rotated
Tip Shape: Rotated
AFM Cantilever:
F
190 kHz
C
45 N/m
L
225 µm


160AC-NN
Standard Tapping Mode AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating:
none
Tip Shape: Optimized Positioning
Tip Shape: Optimized Positioning
AFM Cantilever:
F
300 kHz
C
26 N/m
L
160 µm


Tap300-G
Standard Tapping Mode AFM Probe
Coating:
none
Tip Shape: Rotated
Tip Shape: Rotated
AFM Cantilever:
F
300 kHz
C
40 N/m
L
125 µm


Tap190-G
Tapping Mode AFM Probe with Long AFM Cantilever
Coating:
none
Tip Shape: Rotated
Tip Shape: Rotated
AFM Cantilever:
F
190 kHz
C
48 N/m
L
225 µm
New


biotool cell XXL
Extralong 15 um EBD carbon whisker with 25 nm radius on soft AFM cantilever
Coating:
Reflective Gold
Tip Shape: EBD,Cone Shaped
Tip Shape: EBD,Cone Shaped
AFM Cantilever:
F
50 kHz
C
0.1 N/m
L
60 µm


FESP
Standard Force Modulation AFM Probe
Coating:
none
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
75 kHz
C
2.8 N/m
L
225 µm


240AC-NN
Force Modulation AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating:
none
Tip Shape: Optimized Positioning
Tip Shape: Optimized Positioning
AFM Cantilever:
F
70 kHz
C
2 N/m
L
240 µm


Tap150-G
Soft Tapping Mode AFM Probe
Coating:
none
Tip Shape: Rotated
Tip Shape: Rotated
AFM Cantilever:
F
150 kHz
C
5 N/m
L
125 µm


PPP-FM
Standard Force Modulation AFM Probe
Coating:
none
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
75 kHz
C
2.8 N/m
L
225 µm


FM
Standard Force Modulation AFM Probe
Coating:
none
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
75 kHz
C
2.8 N/m
L
225 µm


ARROW-FM
Force Modulation AFM Probe with Tip at the Very End of the Cantilever
Coating:
none
Tip Shape: Arrow
Tip Shape: Arrow
AFM Cantilever:
F
75 kHz
C
2.8 N/m
L
240 µm


HQ:NSC14/No Al
Soft Tapping Mode AFM Probe
Coating:
none
Tip Shape: Rotated
Tip Shape: Rotated
AFM Cantilever:
F
160 kHz
C
5 N/m
L
125 µm


HQ:NSC18/No Al
Standard Force Modulation AFM Probe
Coating:
none
Tip Shape: Rotated
Tip Shape: Rotated
AFM Cantilever:
F
75 kHz
C
2.8 N/m
L
225 µm


HQ:NSC19/No Al
Standard Force Modulation AFM Probe
Coating:
none
Tip Shape: Rotated
Tip Shape: Rotated
AFM Cantilever:
F
65 kHz
C
0.5 N/m
L
125 µm


Multi75-G
Standard Force Modulation AFM Probe
Coating:
none
Tip Shape: Rotated
Tip Shape: Rotated
AFM Cantilever:
F
75 kHz
C
3 N/m
L
225 µm


SSS-NCL
SuperSharp, Tapping Mode AFM Probe with Long AFM Cantilever
Coating:
none
Tip Shape: Supersharp
Tip Shape: Supersharp
AFM Cantilever:
F
190 kHz
C
48 N/m
L
225 µm


NW-SSS-NCL
SuperSharp, Tapping Mode AFM Probe with Long Cantilever
Coating:
none
Tip Shape: Supersharp
Tip Shape: Supersharp
AFM Cantilever:
F
190 kHz
C
48 N/m
L
225 µm