1 Single AFM Cantilever per AFM Probe

AFM probes with one single AFM cantilever
Sort by:
340 results
55AC-NG
55AC-NG

Gold Coated Ultra High Frequency AFM Probe with AFM Tip at the Very End of the AFM Cantilever

Coating: Reflective Gold
Tip Shape: Optimized Positioning
AFM Cantilever:
F
1200 kHz
C
85 N/m
L
65 µm
top value
55AC-NA
55AC-NA

Ultra High Frequency AFM Probe with AFM Tip at the Very End of the AFM Cantilever

Coating: Reflective Aluminum
Tip Shape: Optimized Positioning
AFM Cantilever:
F
1200 kHz
C
85 N/m
L
65 µm
New
OMCL-AC55TS
OMCL-AC55TS
Ultra High Frequency AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating: Reflective Gold
Tip Shape: Optimized Positioning
AFM Cantilever:
F
1600 kHz
C
85 N/m
L
55 µm
55AC-NN
55AC-NN

Ultra High Frequency AFM Probe with AFM Tip at the Very End of the AFM Cantilever

Coating: none
Tip Shape: Optimized Positioning
AFM Cantilever:
F
1200 kHz
C
85 N/m
L
65 µm
HQ:NSC19/Al BS
HQ:NSC19/Al BS
Standard Force Modulation AFM Probe
Coating: Reflective Aluminum
Tip Shape: Rotated
AFM Cantilever:
F
65 kHz
C
0.5 N/m
L
125 µm
PNP-TRS
PNP-TRS

Silicon Nitride AFM Probe Single Cantilever Compatible with ScanAsyst®** Mode

Coating: Reflective Gold
Tip Shape: Pyramid
AFM Cantilever:
F
67 kHz
C
0.32 N/m
L
100 µm
top value
240AC-NG
240AC-NG
Gold Coated Force Modulation AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating: Reflective Gold
Tip Shape: Optimized Positioning
AFM Cantilever:
F
70 kHz
C
2 N/m
L
240 µm
HQ:NSC15/Cr-Au BS
HQ:NSC15/Cr-Au BS
Gold Coated Tapping Mode AFM Probe
Coating: Reflective Gold
Tip Shape: Rotated
AFM Cantilever:
F
325 kHz
C
40 N/m
L
125 µm
HQ:NSC16/Cr-Au BS
HQ:NSC16/Cr-Au BS
Gold Coated Tapping Mode AFM Probe with Long AFM Cantilever
Coating: Reflective Gold
Tip Shape: Rotated
AFM Cantilever:
F
190 kHz
C
45 N/m
L
225 µm
Tap300GD-G
Tap300GD-G
Gold Coated Tapping Mode AFM Probe
Coating: Reflective Gold
Tip Shape: Rotated
AFM Cantilever:
F
300 kHz
C
40 N/m
L
125 µm
Tap190GD-G
Tap190GD-G
Gold Coated Tapping Mode AFM Probe with Long AFM Cantilever
Coating: Reflective Gold
Tip Shape: Rotated
AFM Cantilever:
F
190 kHz
C
48 N/m
L
225 µm
PPP-CONTSC
PPP-CONTSC
Contact Mode AFM Probe with Short AFM Cantilever
Coating: none
Tip Shape: Standard
AFM Cantilever:
F
25 kHz
C
0.2 N/m
L
225 µm
best of the best
PPP-MFMR
PPP-MFMR
Hard Magnetic, Medium Momentum MFM AFM Probe
Coating: Magnetic
Tip Shape: Standard
AFM Cantilever:
F
75 kHz
C
2.8 N/m
L
225 µm
SSS-MFMR
SSS-MFMR
SuperSharp, Hard Magnetic, Low Momentum MFM AFM Probe
Coating: Magnetic
Tip Shape: Supersharp
AFM Cantilever:
F
75 kHz
C
2.8 N/m
L
225 µm
the industry standard
MFMR
MFMR
Hard Magnetic, Medium Momentum MFM AFM Probe
Coating: Magnetic
Tip Shape: Standard
AFM Cantilever:
F
75 kHz
C
2.8 N/m
L
225 µm
S-MFMR
S-MFMR
Soft Magnetic, Medium Momentum MFM AFM Probe
Coating: Magnetic
Tip Shape: Standard
AFM Cantilever:
F
75 kHz
C
2.8 N/m
L
225 µm
top value
HQ:NSC18/Co-Cr/Al BS
HQ:NSC18/Co-Cr/Al BS
Hard Magnetic, Medium Momentum MFM AFM Probe
Coating: Magnetic
Tip Shape: Rotated
AFM Cantilever:
F
75 kHz
C
2.8 N/m
L
225 µm
top value
240AC-MA
240AC-MA
Hard Magnetic, Medium Momentum AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating: Magnetic
Tip Shape: Optimized Positioning
AFM Cantilever:
F
70 kHz
C
2 N/m
L
240 µm
best bang for your buck
MagneticMulti75-G
MagneticMulti75-G
Hard Magnetic, Medium Momentum AFM Probe
Coating: Magnetic
Tip Shape: Rotated
AFM Cantilever:
F
75 kHz
C
3 N/m
L
225 µm
PPP-NCH
PPP-NCH
Standard Tapping Mode AFM Probe
Coating: none
Tip Shape: Standard
AFM Cantilever:
F
330 kHz
C
42 N/m
L
125 µm
17