NanoAndMore SEA does not ship to your country
1 Single AFM Cantilever per AFM Probe
AFM probes with one single AFM cantilever
Sort by:
340 results
top value
HQ:NSC14/Al BS
Soft Tapping Mode AFM Probe
Coating:
Reflective Aluminum
Tip Shape: Rotated
Tip Shape: Rotated
AFM Cantilever:
F
160 kHz
C
5 N/m
L
125 µm
200AC-NA
Soft Tapping Mode AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating:
Reflective Aluminum
Tip Shape: Optimized Positioning
Tip Shape: Optimized Positioning
AFM Cantilever:
F
135 kHz
C
9 N/m
L
200 µm
New
OMCL-AC200TS
Soft Tapping Mode AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating:
Reflective Aluminum
Tip Shape: Optimized Positioning
Tip Shape: Optimized Positioning
AFM Cantilever:
F
150 kHz
C
9 N/m
L
200 µm
best bang for your buck
Tap150Al-G
Soft Tapping Mode AFM Probe
Coating:
Reflective Aluminum
Tip Shape: Rotated
Tip Shape: Rotated
AFM Cantilever:
F
150 kHz
C
5 N/m
L
125 µm
PPP-NCST
Soft Tapping Mode AFM Probe
Coating:
none
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
160 kHz
C
7.4 N/m
L
150 µm
NCST
Soft Tapping Mode AFM Probe
Coating:
none
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
160 kHz
C
7.4 N/m
L
150 µm
ATEC-FM
Force Modulation AFM Probe with REAL Tip Visibility
Coating:
none
Tip Shape: Visible
Tip Shape: Visible
AFM Cantilever:
F
85 kHz
C
2.8 N/m
L
240 µm
best of the best
PPP-FMR
Standard Force Modulation AFM Probe
Coating:
Reflective Aluminum
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
75 kHz
C
2.8 N/m
L
225 µm
ARROW-FMR
Force Modulation AFM Probe with Tip at the Very End of the Cantilever
Coating:
Reflective Aluminum
Tip Shape: Arrow
Tip Shape: Arrow
AFM Cantilever:
F
75 kHz
C
2.8 N/m
L
240 µm
the industry standard
FMR
Standard Force Modulation AFM Probe
Coating:
Reflective Aluminum
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
75 kHz
C
2.8 N/m
L
225 µm
top value
HQ:NSC18/Al BS
Standard Force Modulation AFM Probe
Coating:
Reflective Aluminum
Tip Shape: Rotated
Tip Shape: Rotated
AFM Cantilever:
F
75 kHz
C
2.8 N/m
L
225 µm
top value
240AC-NA
Force Modulation AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating:
Reflective Aluminum
Tip Shape: Optimized Positioning
Tip Shape: Optimized Positioning
AFM Cantilever:
F
70 kHz
C
2 N/m
L
240 µm
New
OMCL-AC240TS
Force Modulation AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating:
Reflective Aluminum
Tip Shape: Optimized Positioning
Tip Shape: Optimized Positioning
AFM Cantilever:
F
70 kHz
C
2 N/m
L
240 µm
best bang for your buck
Multi75Al-G
Standard Force Modulation AFM Probe
Coating:
Reflective Aluminum
Tip Shape: Rotated
Tip Shape: Rotated
AFM Cantilever:
F
75 kHz
C
3 N/m
L
225 µm
OLTESPA
Force Modulation AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating:
Reflective Aluminum
Tip Shape: Optimized Positioning
Tip Shape: Optimized Positioning
AFM Cantilever:
F
70 kHz
C
2 N/m
L
240 µm
best of the best
SSS-NCHR
SuperSharp, Tapping Mode AFM Probe
Coating:
Reflective Aluminum
Tip Shape: Supersharp
Tip Shape: Supersharp
AFM Cantilever:
F
330 kHz
C
42 N/m
L
125 µm
SSS-NCLR
SuperSharp, Tapping Mode AFM Probe with Long AFM Cantilever
Coating:
Reflective Aluminum
Tip Shape: Supersharp
Tip Shape: Supersharp
AFM Cantilever:
F
190 kHz
C
48 N/m
L
225 µm
SSS-FMR
SuperSharp, Force Modulation AFM Probe
Coating:
Reflective Aluminum
Tip Shape: Supersharp
Tip Shape: Supersharp
AFM Cantilever:
F
75 kHz
C
2.8 N/m
L
225 µm
SSS-NCH
SuperSharp, Tapping Mode AFM Probe
Coating:
none
Tip Shape: Supersharp
Tip Shape: Supersharp
AFM Cantilever:
F
330 kHz
C
42 N/m
L
125 µm
the industry standard
NW-SSS-NCH
SuperSharp, Tapping Mode AFM Probe
Coating:
none
Tip Shape: Supersharp
Tip Shape: Supersharp
AFM Cantilever:
F
320 kHz
C
42 N/m
L
125 µm