NanoAndMore GmbH does not ship to your country
Standard Non-Rotated AFM Tips
AFM probes with standard non-rotated 4-sided pyramidal macroscopic shape of the AFM tips
Sort by:
123 results
SuperSharp Enhanced-soft
Ultrasharp EBD AFM whisker for high-resolution, soft tapping AFM
Coating:
Reflective Aluminum
Tip Shape: Cone Shaped,Supersharp,EBD
Tip Shape: Cone Shaped,Supersharp,EBD
AFM Cantilever:
F
75 kHz
C
2.8 N/m
L
225 µm
DT-CONTR
Diamond Coated Contact Mode AFM Probe
Coating:
Diamond
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
20 kHz
C
0.5 N/m
L
450 µm
best of the best
AR10T-NCHR
High-Aspect-Ratio, Tilt Compensated Tapping Mode AFM Probe
Coating:
Reflective Aluminum
Tip Shape: High-Aspect-Ratio
Tip Shape: High-Aspect-Ratio
AFM Cantilever:
F
330 kHz
C
42 N/m
L
125 µm
AR5T-NCHR
High-Aspect-Ratio, Tilt Compensated Tapping Mode AFM Probe
Coating:
Reflective Aluminum
Tip Shape: High-Aspect-Ratio
Tip Shape: High-Aspect-Ratio
AFM Cantilever:
F
330 kHz
C
42 N/m
L
125 µm
the industry standard
NW-AR5T-NCHR
High-Aspect-Ratio, Tilt Compensated Tapping Mode AFM Probe
Coating:
Reflective Aluminum
Tip Shape: High-Aspect-Ratio
Tip Shape: High-Aspect-Ratio
AFM Cantilever:
F
330 kHz
C
42 N/m
L
125 µm
TESPA-HAR
High-Aspect-Ratio, Tapping Mode AFM Probe
Coating:
Reflective Aluminum
Tip Shape: High-Aspect-Ratio
Tip Shape: High-Aspect-Ratio
AFM Cantilever:
F
320 kHz
C
42 N/m
L
125 µm
PPP-CONT
Standard Contact Mode AFM Probe
Coating:
none
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
13 kHz
C
0.2 N/m
L
450 µm
CONT
Standard Contact Mode AFM Probe
Coating:
none
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
13 kHz
C
0.2 N/m
L
450 µm
ESPA
Standard Contact Mode AFM Probe
Coating:
Reflective Aluminum
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
13 kHz
C
0.2 N/m
L
450 µm
CONTSCR
Contact Mode AFM Probe with Short Cantilever
Coating:
Reflective Aluminum
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
25 kHz
C
0.2 N/m
L
225 µm
CONTSC
Contact Mode AFM Probe with Short Cantilever
Coating:
none
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
25 kHz
C
0.2 N/m
L
225 µm
PPP-CONTAuD
Gold Coated Contact Mode AFM Probe
Coating:
Reflective Gold
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
13 kHz
C
0.2 N/m
L
450 µm
PPP-CONTSCAuD
Gold Coated Contact Mode AFM Probe with Short AFM Cantilever
Coating:
Reflective Gold
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
25 kHz
C
0.2 N/m
L
225 µm
PPP-BSI
Soft Contact AFM Probe for Biological Applications
Coating:
none
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
28 kHz
C
0.1 N/m
L
225 µm
EBD-AR15T
High-aspect ratio, tilt compensated EBD AFM whisker for automated non-contact AFM
Coating:
none
Tip Shape: High-Aspect-Ratio,Cone Shaped,EBD
Tip Shape: High-Aspect-Ratio,Cone Shaped,EBD
AFM Cantilever:
F
330 kHz
C
40 N/m
L
125 µm
AR10-NCHR
High-Aspect-Ratio, Tapping Mode AFM Probe
Coating:
Reflective Aluminum
Tip Shape: High-Aspect-Ratio
Tip Shape: High-Aspect-Ratio
AFM Cantilever:
F
330 kHz
C
42 N/m
L
125 µm
AR5-NCHR
High-Aspect-Ratio, Tapping Mode AFM Probe
Coating:
Reflective Aluminum
Tip Shape: High-Aspect-Ratio
Tip Shape: High-Aspect-Ratio
AFM Cantilever:
F
330 kHz
C
42 N/m
L
125 µm
AR5-NCH
High-Aspect-Ratio, Tapping Mode AFM Probe
Coating:
none
Tip Shape: High-Aspect-Ratio
Tip Shape: High-Aspect-Ratio
AFM Cantilever:
F
330 kHz
C
42 N/m
L
125 µm
NW-AR10-NCHR
High-Aspect-Ratio, Tapping Mode AFM Probe
Coating:
Reflective Aluminum
Tip Shape: High-Aspect-Ratio
Tip Shape: High-Aspect-Ratio
AFM Cantilever:
F
320 kHz
C
42 N/m
L
125 µm
NW-AR5-NCHR
High-Aspect-Ratio, Tapping Mode AFM Probe
Coating:
Reflective Aluminum
Tip Shape: High-Aspect-Ratio
Tip Shape: High-Aspect-Ratio
AFM Cantilever:
F
320 kHz
C
42 N/m
L
125 µm