NanoAndMore GmbH does not ship to your country
Standard Non-Rotated AFM Tips
AFM probes with standard non-rotated 4-sided pyramidal macroscopic shape of the AFM tips
Sort by:
123 results
best of the best
DT-NCHR
Diamond Coated Tapping Mode AFM Probe
Coating:
Diamond
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
400 kHz
C
80 N/m
L
125 µm
DT-FMR
Diamond Coated Force Modulation AFM Probe
Coating:
Diamond
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
105 kHz
C
6.2 N/m
L
225 µm
DT-NCLR
Diamond Coated Tapping Mode AFM Probe with Long AFM Cantilever
Coating:
Diamond
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
210 kHz
C
72 N/m
L
225 µm
the industry standard
NW-DT-NCHR
Diamond Coated Tapping Mode AFM Probe
Coating:
Diamond
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
400 kHz
C
80 N/m
L
125 µm
NW-DT-FMR
Diamond Coated Force Modulation AFM Probe
Coating:
Diamond
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
105 kHz
C
6.2 N/m
L
225 µm
NW-DT-NCLR
Diamond Coated Tapping Mode AFM Probe with Long Cantilever
Coating:
Diamond
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
210 kHz
C
72 N/m
L
225 µm
PPP-NCHAuD
Gold Coated Tapping Mode AFM Probe
Coating:
Reflective Gold
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
330 kHz
C
42 N/m
L
125 µm
PPP-QFMR
Force Modulation AFM Probe, for UHV Conditions
Coating:
Reflective Aluminum
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
75 kHz
C
2.8 N/m
L
225 µm
best of the best
PPP-CONTR
Standard Contact Mode AFM Probe
Coating:
Reflective Aluminum
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
13 kHz
C
0.2 N/m
L
450 µm
best of the best
PPP-LFMR
Standard Lateral Force Mode AFM Probes
Coating:
Reflective Aluminum
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
23 kHz
C
0.2 N/m
L
225 µm
the industry standard
CONTR
Standard Contact Mode AFM Probe
Coating:
Reflective Aluminum
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
13 kHz
C
0.2 N/m
L
450 µm
best of the best
CDT-FMR
Diamond Coated, Conductive Force Modulation AFM Probe
Coating:
Diamond,Conductive Diamond
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
105 kHz
C
6.2 N/m
L
225 µm
best of the best
PPP-EFM
Electrical, Force Modulation AFM Probe
Coating:
Electrically Conductive
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
75 kHz
C
2.8 N/m
L
225 µm
the industry standard
NW-CDT-FMR
Diamond Coated, Conductive Force Modulation AFM Probe
Coating:
Diamond,Conductive Diamond
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
105 kHz
C
6.2 N/m
L
225 µm
the industry standard
EFM
Electrical, Force Modulation AFM Probe
Coating:
Electrically Conductive
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
75 kHz
C
2.8 N/m
L
225 µm
CDT-CONTR
Diamond Coated, Conductive Contact Mode AFM Probe
Coating:
Diamond,Conductive Diamond
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
20 kHz
C
0.5 N/m
L
450 µm
DDESP
Diamond Coated, Conductive Tapping Mode AFM Probe
Coating:
Diamond
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
400 kHz
C
80 N/m
L
125 µm
DDESP-FM
Diamond Coated, Conductive Force Modulation AFM Probe
Coating:
Diamond
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
105 kHz
C
6.2 N/m
L
225 µm
PPP-NCSTAuD
Gold Coated Soft Tapping Mode AFM Probe
Coating:
Reflective Gold
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
160 kHz
C
7.4 N/m
L
150 µm
PPP-FMAuD
Gold Coated Force Modulation AFM Probe
Coating:
Reflective Gold
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
75 kHz
C
2.8 N/m
L
225 µm