NanoAndMore SEA does not ship to your country
Tipless AFM Cantilevers
Special AFM probes with tipless AFM cantilevers
Sort by:
29 results
best of the best
TL-CONT
Tipless Contact Mode AFM Cantilever
Coating:
none
Tip Shape: Tipless
Tip Shape: Tipless
AFM Cantilever:
F
13 kHz
C
0.2 N/m
L
450 µm
TL-FM
Tipless Force Modulation AFM Cantilever
Coating:
none
Tip Shape: Tipless
Tip Shape: Tipless
AFM Cantilever:
F
75 kHz
C
2.8 N/m
L
225 µm
TL-NCH
Tipless Tapping Mode AFM Cantilever
Coating:
none
Tip Shape: Tipless
Tip Shape: Tipless
AFM Cantilever:
F
330 kHz
C
42 N/m
L
125 µm
TL-NCL
Tipless, Long Tapping Mode AFM Cantilever
Coating:
none
Tip Shape: Tipless
Tip Shape: Tipless
AFM Cantilever:
F
190 kHz
C
48 N/m
L
225 µm
the industry standard
ARROW-TL1
Tipless AFM Cantilever for Special Applications
Coating:
none
Tip Shape: Tipless
Tip Shape: Tipless
AFM Cantilever:
F
6 kHz
C
0.03 N/m
L
500 µm
PNP-TR-TL
Tipless Silicon Nitride AFM Cantilever
Coating:
Reflective Gold
Tip Shape: Tipless
Tip Shape: Tipless
AFM Cantilevers: 2
1
2
F
67 kHz
17 kHz
C
0.32 N/m
0.08 N/m
L
100 µm
200 µm
ARROW-TL2
Tipless AFM Cantilever Array for Special Applications
Coating:
none
Tip Shape: Tipless
Tip Shape: Tipless
AFM Cantilevers: 2
1
F
6 kHz
C
0.03 N/m
L
500 µm
ARROW-TL8
Tipless AFM Cantilever Array for Special Applications
Coating:
none
Tip Shape: Tipless
Tip Shape: Tipless
AFM Cantilevers: 8
1
F
6 kHz
C
0.03 N/m
L
500 µm
HQ:NSC35/tipless/No Al
Tipless AFM Probe with 3 Different Tapping Mode AFM Cantilevers
Coating:
none
Tip Shape: Tipless
Tip Shape: Tipless
AFM Cantilevers: 3
1
2
3
F
205 kHz
300 kHz
150 kHz
C
8.9 N/m
16 N/m
5.4 N/m
L
110 µm
90 µm
130 µm
HQ:NSC36/tipless/No Al
Tipless AFM Probe with 3 Different Force Modulation AFM Cantilevers
Coating:
none
Tip Shape: Tipless
Tip Shape: Tipless
AFM Cantilevers: 3
1
2
3
F
90 kHz
130 kHz
65 kHz
C
1 N/m
2 N/m
0.6 N/m
L
110 µm
90 µm
130 µm
HQ:CSC37/tipless/No Al
Tipless AFM Probe with 3 Different Contact Mode AFM Cantilevers
Coating:
none
Tip Shape: Tipless
Tip Shape: Tipless
AFM Cantilevers: 3
1
2
3
F
40 kHz
20 kHz
30 kHz
C
0.8 N/m
0.3 N/m
0.4 N/m
L
250 µm
350 µm
300 µm
top value
HQ:CSC38/tipless/No Al
Tipless AFM Probe with 3 Different Contact Mode AFM Cantilevers
Coating:
none
Tip Shape: Tipless
Tip Shape: Tipless
AFM Cantilevers: 3
1
2
3
F
20 kHz
10 kHz
14 kHz
C
0.09 N/m
0.03 N/m
0.05 N/m
L
250 µm
350 µm
300 µm
best bang for your buck
All-In-One-Tipless
Tipless AFM Probe with 4 Different AFM Cantilevers for Various Applications
Coating:
none
Tip Shape: Tipless
Tip Shape: Tipless
AFM Cantilevers: 4
1
2
3
4
F
15 kHz
80 kHz
150 kHz
350 kHz
C
0.2 N/m
2.7 N/m
7.4 N/m
40 N/m
L
500 µm
210 µm
150 µm
100 µm
ARROW-TL1Au
Tipless, Gold Coated AFM Cantilever Array for Special Applications
Coating:
Gold on Sample Facing Side
Tip Shape: Tipless
Tip Shape: Tipless
AFM Cantilever:
F
6 kHz
C
0.03 N/m
L
500 µm
ARROW-TL2Au
Tipless, Gold Coated AFM Cantilever Array for Special Applications
Coating:
Gold on Sample Facing Side
Tip Shape: Tipless
Tip Shape: Tipless
AFM Cantilevers: 2
1
F
6 kHz
C
0.03 N/m
L
500 µm
ARROW-TL8Au
Tipless, Gold Coated AFM Cantilever Array for Special Applications
Coating:
Gold on Sample Facing Side
Tip Shape: Tipless
Tip Shape: Tipless
AFM Cantilevers: 8
1
F
6 kHz
C
0.03 N/m
L
500 µm
PNP-TR-TL-Au
Tipless, Gold Coated Silicon Nitride AFM Cantilever
Coating:
Gold Overall
Tip Shape: Tipless
Tip Shape: Tipless
AFM Cantilevers: 2
1
2
F
67 kHz
17 kHz
C
0.32 N/m
0.08 N/m
L
100 µm
200 µm
HQ:NSC35/tipless/Cr-Au
Tipless AFM Probe with 3 Different Gold Coated Tapping Mode AFM Cantilevers
Coating:
Gold Overall
Tip Shape: Tipless
Tip Shape: Tipless
AFM Cantilevers: 3
1
2
3
F
205 kHz
300 kHz
150 kHz
C
8.9 N/m
16 N/m
5.4 N/m
L
110 µm
90 µm
130 µm
Mix and Match Box
Mixed box: up to 400 MikroMasch AFM probes
Coating:
various
Tip Shape: various
Tip Shape: various
HQ:NSC36/tipless/Cr-Au
Tipless AFM Probe with 3 Different Gold Coated Force Modulation AFM Cantilevers
Coating:
Gold Overall
Tip Shape: Tipless
Tip Shape: Tipless
AFM Cantilevers: 3
1
2
3
F
90 kHz
130 kHz
65 kHz
C
1 N/m
2 N/m
0.6 N/m
L
110 µm
90 µm
130 µm