NanoAndMore SEA does not ship to your country
Silicon AFM Cantilevers
AFM probes with silicon AFM cantilevers
Sort by:
372 results
ARROW-FM
Force Modulation AFM Probe with Tip at the Very End of the Cantilever
Coating:
none
Tip Shape: Arrow
Tip Shape: Arrow
AFM Cantilever:
F
75 kHz
C
2.8 N/m
L
240 µm
HQ:NSC14/No Al
Soft Tapping Mode AFM Probe
Coating:
none
Tip Shape: Rotated
Tip Shape: Rotated
AFM Cantilever:
F
160 kHz
C
5 N/m
L
125 µm
HQ:NSC18/No Al
Standard Force Modulation AFM Probe
Coating:
none
Tip Shape: Rotated
Tip Shape: Rotated
AFM Cantilever:
F
75 kHz
C
2.8 N/m
L
225 µm
HQ:NSC19/No Al
Standard Force Modulation AFM Probe
Coating:
none
Tip Shape: Rotated
Tip Shape: Rotated
AFM Cantilever:
F
65 kHz
C
0.5 N/m
L
125 µm
HQ:NSC35/No Al
AFM Probe with 3 Different Tapping Mode AFM Cantilevers
Coating:
none
Tip Shape: Rotated
Tip Shape: Rotated
AFM Cantilevers: 3
1
2
3
F
205 kHz
300 kHz
150 kHz
C
8.9 N/m
16 N/m
5.4 N/m
L
110 µm
90 µm
130 µm
HQ:NSC36/No Al
AFM Probe with 3 Different Force Modulation Mode AFM Cantilevers
Coating:
none
Tip Shape: Rotated
Tip Shape: Rotated
AFM Cantilevers: 3
1
2
3
F
90 kHz
130 kHz
65 kHz
C
1 N/m
2 N/m
0.6 N/m
L
110 µm
90 µm
130 µm
Multi75-G
Standard Force Modulation AFM Probe
Coating:
none
Tip Shape: Rotated
Tip Shape: Rotated
AFM Cantilever:
F
75 kHz
C
3 N/m
L
225 µm
3XC-NN
AFM Probe with 3 Different AFM Cantilevers for Various Applications and AFM Tips at the Very End of the AFM Cantilevers
Coating:
none
Tip Shape: Optimized Positioning
Tip Shape: Optimized Positioning
AFM Cantilevers: 3
1
2
3
F
17 kHz
150 kHz
75 kHz
C
0.3 N/m
9 N/m
2.5 N/m
L
500 µm
175 µm
240 µm
HQ:XSC11/No Al
AFM Probe with 4 Different Cantilevers for Various Applications
Coating:
none
Tip Shape: Rotated
Tip Shape: Rotated
AFM Cantilevers: 4
1
2
3
4
F
15 kHz
80 kHz
155 kHz
350 kHz
C
0.2 N/m
2.7 N/m
7 N/m
42 N/m
L
500 µm
210 µm
150 µm
100 µm
All-In-One
AFM Probe with 4 Different AFM Cantilevers for Various Applications
Coating:
none
Tip Shape: Rotated
Tip Shape: Rotated
AFM Cantilevers: 4
1
2
3
4
F
15 kHz
80 kHz
150 kHz
350 kHz
C
0.2 N/m
2.7 N/m
7.4 N/m
40 N/m
L
500 µm
210 µm
150 µm
100 µm
SSS-NCL
SuperSharp, Tapping Mode AFM Probe with Long AFM Cantilever
Coating:
none
Tip Shape: Supersharp
Tip Shape: Supersharp
AFM Cantilever:
F
190 kHz
C
48 N/m
L
225 µm
NW-SSS-NCL
SuperSharp, Tapping Mode AFM Probe with Long Cantilever
Coating:
none
Tip Shape: Supersharp
Tip Shape: Supersharp
AFM Cantilever:
F
190 kHz
C
48 N/m
L
225 µm
SSS-FM
SuperSharp, Force Modulation AFM Probe
Coating:
none
Tip Shape: Supersharp
Tip Shape: Supersharp
AFM Cantilever:
F
75 kHz
C
2.8 N/m
L
225 µm
HiRes-C18/Cr-Au
High Resolution, Soft Tapping Mode AFM Probe
Coating:
Reflective Gold
Tip Shape: Supersharp
Tip Shape: Supersharp
AFM Cantilever:
F
75 kHz
C
2.8 N/m
L
225 µm
HiRes-C14/Cr-Au
High Resolution, Soft Tapping Mode AFM Probe
Coating:
Reflective Gold
Tip Shape: Supersharp
Tip Shape: Supersharp
AFM Cantilever:
F
160 kHz
C
5 N/m
L
125 µm
SHR300
High Resolution Tapping Mode AFM Probe
Coating:
Reflective Gold
Tip Shape: Supersharp
Tip Shape: Supersharp
AFM Cantilever:
F
300 kHz
C
40 N/m
L
125 µm
SuperSharp Enhanced
Ultrasharp EBD AFM whisker for high-resolution, non-contact AFM
Coating:
Reflective Aluminum
Tip Shape: Cone Shaped,Supersharp,EBD
Tip Shape: Cone Shaped,Supersharp,EBD
AFM Cantilever:
F
320 kHz
C
40 N/m
L
120 µm
SuperSharpStandard-NCH
SuperSharp diamond-like EBD whisker for non-contact AFM
Coating:
Reflective Aluminum
Tip Shape: Cone Shaped,Supersharp,EBD
Tip Shape: Cone Shaped,Supersharp,EBD
AFM Cantilever:
F
330 kHz
C
40 N/m
L
125 µm
SuperSharp Enhanced-soft
Ultrasharp EBD AFM whisker for high-resolution, soft tapping AFM
Coating:
Reflective Aluminum
Tip Shape: Cone Shaped,Supersharp,EBD
Tip Shape: Cone Shaped,Supersharp,EBD
AFM Cantilever:
F
75 kHz
C
2.8 N/m
L
225 µm
HQ:NSC16/Hard/Al BS
Long Scanning, DLC Hardened Tapping Mode AFM Probe with Long AFM Cantilever
Coating:
Hard Diamond-Like-Carbon
Tip Shape: Rotated
Tip Shape: Rotated
AFM Cantilever:
F
190 kHz
C
45 N/m
L
225 µm