AFM Probes  »  
 Request a quote (RFQ)
Order Code / Price*
Quantity
ATEC-CONTAu-10 Box of 10 AFM Probes
890.00 USD
Price shown as ex-works and subjected to shipping charges, insurance, local VAT and custom duties respectively where applicable

ATEC-CONTAu

Gold Coated Contact Mode AFM Probe with REAL Tip Visibility

Manufacturer: NANOSENSORS

Coating: Gold Overall
AFM tip shape: Visible
AFM Cantilever
F 15 kHz
C 0.2 N/m
L 450 µm
*nominal values
Applications
How to optimize AFM scan parameters gear icon

NANOSENSORS™ AdvancedTEC™ ContAu AFM probes are designed for contact mode imaging. They feature a tetrahedral AFM tip that protrudes from the very end of the AFM cantilever.

This unique feature allows precise positioning and makes the AdvancedTEC™ the only AFM probe in the world that offers REAL TIP VISIBILITY FROM TOP, even when the AFM probe is tilted due to its mounting onto the AFM head. This feature makes them the premium choice for all applications where the AFM tip has to be placed exactly on the point of interest and/or has to be visible (e.g. Nanomanipulation).

Due to their very small half cone angles the AFM tips of the AdvancedTEC™Series show great performance on samples that have a small pattern size combined with steep sample features.

The AFM probe offers unique features:

  • REAL TIP VISIBILITY FROM TOP
  • metallic conductivity of the AFM tip
  • high mechanical Q-factor for high sensitivity
  • aspect ratio of the last 1.5 µm of the AFM tip > 4:1 (from front and side)
  • AFM tip shape is defined by real crystal planes resulting in highly reproducible geometries and extremely smooth surfaces
  • highly doped single crystal silicon (0.01-0.025 Ohm*cm)
  • rectangular AFM cantilever with trapezoidal cross section
  • holder dimensions are 1.6 mm x 3.4 mm

Please note: Wear at the AFM tip can occur if operating in contact-, friction- or force modulation mode or where it is necessary to conduct high currents.

The metallic coating is an approximately 70 nm thick double layer of chromium and gold on both sides of the AFM cantilever.

The AFM tip side coating enhances the conductivity of the AFM tip and allows electrical contacts.

The detector side coating enhances the reflectivity of the laser beam by a factor of about 2 and prevents light from interfering within the AFM cantilever. The coating process is optimized for stress compensation and wear resistance.

As the coating is nearly stress-free the bending of the AFM cantilever due to stress is less than 2 degrees.

AFM Tip:

  • AFM Cantilever:
  • Beam
  • 0.2 N/m (0.02 - 0.75 N/m)*
  • 15 kHz (7 - 25 kHz)*
  • 450 µm (440 - 460 µm)*
  • 50 µm (45 - 55 µm)*
  • 2 µm ( 1 - 3 µm)*
  • * guaranteed range
    Loading
    nanosensors-logo
    nanoworld-logo
    budgetsensors-logo
    mikromasch-logo
    opus-logo
    sqube-logo
    nanotools-logo