NanoAndMore GmbH does not ship to your country
Fluid Tapping AFM Probes
AFM probes with gold reflective or gold overall AFM cantilever coating for tapping mode measurements on life science samples in liquid or buffer solution
Sort by:
36 results
Mix and Match Box
Mixed box: up to 400 MikroMasch AFM probes
Coating:
various
Tip Shape: various
Tip Shape: various
ATEC-FMAu
Gold Coated Force Modulation AFM Probe with REAL Tip Visibility
Coating:
Gold Overall
Tip Shape: Visible
Tip Shape: Visible
AFM Cantilever:
F
85 kHz
C
2.8 N/m
L
240 µm
PPP-FMAu
Gold Coated Force Modulation AFM Probe
Coating:
Gold Overall
Tip Shape: Standard
Tip Shape: Standard
AFM Cantilever:
F
75 kHz
C
2.8 N/m
L
225 µm
PNP-TR-Au
Gold Coated Silicon Nitride AFM Probe
Coating:
Gold Overall
Tip Shape: Pyramid
Tip Shape: Pyramid
AFM Cantilevers: 2
1
2
F
67 kHz
17 kHz
C
0.32 N/m
0.08 N/m
L
100 µm
200 µm
USC-F1.5-k0.6
Ultra-Short Cantilever (USC) mainly dedicated to High-Speed AFM applications in liquid
Coating:
Reflective Gold
Tip Shape: Cone Shaped,EBD
Tip Shape: Cone Shaped,EBD
AFM Cantilever:
F
1500 kHz
C
0.6 N/m
L
7 µm
HQ:NSC18/Cr-Au
Gold Coated Force Modulation AFM Probe
Coating:
Gold Overall
Tip Shape: Rotated
Tip Shape: Rotated
AFM Cantilever:
F
75 kHz
C
2.8 N/m
L
225 µm
HQ:NSC19/Cr-Au
Gold Coated Force Modulation AFM Probe
Coating:
Gold Overall
Tip Shape: Rotated
Tip Shape: Rotated
AFM Cantilever:
F
65 kHz
C
0.5 N/m
L
125 µm
HQ:NSC35/Cr-Au
AFM Probe with 3 Different Gold Coated Tapping Mode AFM Cantilevers
Coating:
Gold Overall
Tip Shape: Rotated
Tip Shape: Rotated
AFM Cantilevers: 3
1
2
3
F
205 kHz
300 kHz
150 kHz
C
8.9 N/m
16 N/m
5.4 N/m
L
110 µm
90 µm
130 µm
HQ:NSC36/Cr-Au
AFM Probe with 3 Different Gold Coated Force Modulation Mode AFM Cantilevers
Coating:
Gold Overall
Tip Shape: Rotated
Tip Shape: Rotated
AFM Cantilevers: 3
1
2
3
F
90 kHz
130 kHz
65 kHz
C
1 N/m
2 N/m
0.6 N/m
L
110 µm
90 µm
130 µm
3XC-GG
AFM Probe with 3 Different Gold Coated AFM Cantilevers for Various Applications and AFM Tips at the Very End of the AFM Cantilevers
Coating:
Gold Overall
Tip Shape: Optimized Positioning
Tip Shape: Optimized Positioning
AFM Cantilevers: 3
1
2
3
F
17 kHz
150 kHz
75 kHz
C
0.3 N/m
9 N/m
2.5 N/m
L
500 µm
175 µm
240 µm
4XC-GG
AFM Probe with 4 Different Gold Coated AFM Cantilevers with AFM Tips at the Very End of the AFM Cantilevers
Coating:
Gold Overall
Tip Shape: Optimized Positioning
Tip Shape: Optimized Positioning
AFM Cantilevers: 4
1
2
3
4
F
17 kHz
75 kHz
150 kHz
1200 kHz
C
0.3 N/m
2.5 N/m
9 N/m
100 N/m
L
500 µm
240 µm
175 µm
65 µm
240AC-GG
Gold Coated Force Modulation AFM Probe with AFM Tip at the Very End of the AFM Cantilever
Coating:
Gold Overall
Tip Shape: Optimized Positioning
Tip Shape: Optimized Positioning
AFM Cantilever:
F
70 kHz
C
2 N/m
L
240 µm
Multi75GB-G
Gold Coated Force Modulation AFM Probe
Coating:
Gold Overall
Tip Shape: Rotated
Tip Shape: Rotated
AFM Cantilever:
F
75 kHz
C
3 N/m
L
225 µm
BudgetComboBox
Mixed Box with 50 BudgetSensors AFM probes of your choice
Coating:
various
Tip Shape: various
Tip Shape: various
New
BL-AC40TS
Tapping Mode AFM Probe for High-Speed Scanning in Liquids
Coating:
Reflective Gold
Tip Shape: Optimized Positioning
Tip Shape: Optimized Positioning
AFM Cantilever:
F
110 kHz
C
0.1 N/m
L
38 µm
NANOSENSORS™ Special Developments List (SDL)
Special AFM Probes etc. Showcasing NANOSENSORS™ Expertise
Coating:
various
Tip Shape: various
Tip Shape: various