| type |
manufacturer |
short description |
short specs: |
tip shape |
LRCH-225C0_7-R |
 |
Special Nanoindentation AFM probe |
coating:Reflex Aluminum AFM cantilever: length: 225 µm force const.: 0.7 N/m res. freq.: 45 kHz
|
Cone Shaped |
LRCH-225C3_0-R |
 |
Special Nanoindentation AFM probe |
coating:Reflex Aluminum AFM cantilever: length: 225 µm force const.: 3 N/m res. freq.: 75 kHz
|
Cone Shaped |
PPP-NCHAu |
 |
Gold Coated Tapping Mode AFM Probe |
coating:Gold Overall AFM cantilever: length: 125 µm force const.: 42 N/m res. freq.: 330 kHz
|
Standard |
PPP-NCLAu |
 |
Gold Coated Tapping Mode AFM Probe with Long Cantilever |
coating:Gold Overall AFM cantilever: length: 225 µm force const.: 48 N/m res. freq.: 190 kHz
|
Standard |
PPP-NCSTAu |
 |
Gold Coated Soft Tapping Mode AFM Probe |
coating:Gold Overall AFM cantilever: length: 150 µm force const.: 7.4 N/m res. freq.: 160 kHz
|
Standard |
PPP-FMAu |
 |
Gold Coated Force Modulation AFM Probe |
coating:Gold Overall AFM cantilever: length: 225 µm force const.: 2.8 N/m res. freq.: 75 kHz
|
Standard |
PPP-CONTAu |
 |
Gold Coated Contact Mode AFM Probe |
coating:Gold Overall AFM cantilever: length: 450 µm force const.: 0.2 N/m res. freq.: 13 kHz
|
Standard |
PPP-CONTSCAu |
 |
Gold Coated Contact Mode AFM Probe with Short Cantilever |
coating:Gold Overall AFM cantilever: length: 225 µm force const.: 0.2 N/m res. freq.: 23 kHz
|
Standard |
PPP-CONTSCAuD |
 |
Gold Coated Contact Mode AFM Probe with Short Cantilever |
coating:Gold Overall AFM cantilever: length: 225 µm force const.: 0.2 N/m res. freq.: 23 kHz
|
Standard |
 ATEC-NCAu |
 |
Gold Coated Tapping Mode AFM Probe with a REAL Visible Tip |
coating:Gold Overall AFM cantilever: length: 160 µm force const.: 45 N/m res. freq.: 335 kHz
|
Visible |
 ATEC-FMAu |
 |
Gold Coated Force Modulation AFM Probe with a REAL Visible Tip |
coating:Gold Overall AFM cantilever: length: 240 µm force const.: 2.8 N/m res. freq.: 85 kHz
|
Visible |
 ATEC-CONTAu |
 |
Gold Coated Contact Mode AFM Probe with a REAL Visible Tip |
coating:Gold Overall AFM cantilever: length: 450 µm force const.: 0.2 N/m res. freq.: 15 kHz
|
Visible |
PNP-TR |
 |
Silicon Nitride AFM Probe |
coating:Reflex Chromium/Gold AFM cantilever: length: 200 µm force const.: 0.08 N/m res. freq.: 17 kHz AFM cantilever: length: 100 µm force const.: 0.32 N/m res. freq.: 67 kHz
|
Pyramid |
PNP-DB |
 |
Silicon Nitride AFM Probe |
coating:Reflex Chromium/Gold AFM cantilever: length: 200 µm force const.: 0.06 N/m res. freq.: 17 kHz AFM cantilever: length: 100 µm force const.: 0.48 N/m res. freq.: 67 kHz
|
Pyramid |
Tap300GB |
 |
Gold Coated Tapping Mode AFM Probe |
coating:Gold Overall AFM cantilever: length: 125 µm force const.: 40 N/m res. freq.: 300 kHz
|
Rotated |
Tap300GD |
 |
Gold Coated Tapping Mode AFM Probe |
coating:Reflex Gold AFM cantilever: length: 125 µm force const.: 40 N/m res. freq.: 300 kHz
|
Rotated |
Multi75GB |
 |
Gold Coated Force Modulation AFM Probe |
coating:Gold Overall AFM cantilever: length: 225 µm force const.: 3 N/m res. freq.: 75 kHz
|
Rotated |
Multi75GD |
 |
Gold Coated Force Modulation AFM Probe |
coating:Reflex Gold AFM cantilever: length: 225 µm force const.: 3 N/m res. freq.: 75 kHz
|
Rotated |
ContGB-G |
 |
Gold Coated Contact Mode AFM Probe |
coating:Gold Overall AFM cantilever: length: 450 µm force const.: 0.2 N/m res. freq.: 13 kHz
|
Rotated |
ContGD |
 |
Gold Coated Contact Mode AFM Probe |
coating:Reflex Gold AFM cantilever: length: 450 µm force const.: 0.2 N/m res. freq.: 13 kHz
|
Rotated |
ARROW-UHF |
 |
Ultra High Frequency AFM Probe with Tip at the Very End of the Cantilever |
coating:Reflex Aluminum AFM cantilever: length: 35 µm force const.: - res. freq.: 1.5 kHz
|
Arrow |
PPP-NCVH |
 |
Tapping Mode AFM Probe with a High Mechanical Q-Factor |
coating:None AFM cantilever: length: 50 µm force const.: 140 N/m res. freq.: 1100 kHz
|
Standard |
PPP-NCSTAuD |
 |
|
coating:Reflex Gold AFM cantilever: length: 150 µm force const.: 7.4 N/m res. freq.: 160 kHz
|
Standard |
PPP-NCHAuD |
 |
|
coating:Reflex Gold AFM cantilever: length: 125 µm force const.: 42 N/m res. freq.: 330 kHz
|
Standard |
PPP-FMAuD |
 |
|
coating:Reflex Gold AFM cantilever: length: 225 µm force const.: 2.8 N/m res. freq.: 75 kHz
|
Standard |
PPP-CONTAuD |
 |
|
coating:Reflex Gold AFM cantilever: length: 450 µm force const.: 0.2 N/m res. freq.: 13 kHz
|
Standard |
SiNi |
 |
|
coating:Reflex Chromium/Gold AFM cantilever: length: 200 µm force const.: 0.06 N/m res. freq.: 10 kHz AFM cantilever: length: 100 µm force const.: 0.27 N/m res. freq.: 30 kHz
|
Pyramid |
BudgetComboBox |
 |
Mixed Box with 50 BudgetSensors AFM probes of your choice |
|
|
PL2-NCH |
 |
Tapping Mode AFM Probe with Plateau Tip |
coating:None AFM cantilever: length: 125 µm force const.: 42 N/m res. freq.: 330 kHz
|
Plateau |
PL2-NCHR |
 |
Tapping Mode AFM Probe with Plateau Tip |
coating:Reflex Aluminum AFM cantilever: length: 125 µm force const.: 42 N/m res. freq.: 330 kHz
|
Plateau |
PL2-FM |
 |
Force Modulation AFM Probe with Plateau Tip |
coating:None AFM cantilever: length: 225 µm force const.: 2.8 N/m res. freq.: 75 kHz
|
Plateau |
PL2-FMR |
 |
Force Modulation AFM Probe with Plateau Tip |
coating:Reflex Aluminum AFM cantilever: length: 225 µm force const.: 2.8 N/m res. freq.: 75 kHz
|
Plateau |
PL2-NCL |
 |
Tapping Mode AFM Probe with Long Cantilever and Plateau Tip |
coating:None AFM cantilever: length: 225 µm force const.: 48 N/m res. freq.: 190 kHz
|
Plateau |
PL2-NCLR |
 |
Tapping Mode AFM Probe with Long Cantilever and Plateau Tip |
coating:Reflex Aluminum AFM cantilever: length: 125 µm force const.: 42 N/m res. freq.: 330 kHz
|
Plateau |
PL2-CONT |
 |
Contact Mode AFM Probe with Plateau Tip |
coating:None AFM cantilever: length: 450 µm force const.: 0.2 N/m res. freq.: 13 kHz
|
Plateau |
PL2-CONTR |
 |
Contact Mode AFM Probe with Plateau Tip |
coating:Reflex Aluminum AFM cantilever: length: 450 µm force const.: 0.2 N/m res. freq.: 13 kHz
|
Plateau |